ArticlePloS one2025
Structural optimization of pit bionic drip irrigation emitter to improve hydraulic performance and anti-clogging performance.
Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The blockage inside the flow channel of drip irrigation emitters is a key issue that restricts their usability. The low-speed vortex zone that exists in traditional channel design is the core reason. This study designed four different structures of pit bionic drip irrigation emitters based on the principles of plant bionics. The computational fluid dynamics (CFD) numerical simulation method was adopted and the flow velocity and turbulence energy of four structures were analyzed. The discrete element method (DEM) was combined to study the motion trajectory of 0.1 mm sand particles. The results indicate that schemes 1, 2, and 4 all have significant low-speed vortices in the return water zone (D zone). The situation in scheme 3 is relatively mild and the probability of sand particles depositing in the channel decreases. The flow channel structure was further optimized based on the original foundation and eight types of sand particles with different sizes were selected for anti clogging experiments. The relative traffic of the optimized model in the third and fourth stages was 13.34% and 14.51% higher. In terms of the sensitive particle size causing blockage, the maximum allowable particle size of the optimized flow channel structure was nearly twice that of scheme 3. When the particle size was 0.120, 0.165, 0.187, 0.212, and 0.245 mm, the sedimentation rate was reduced by an average of 58.02%. This study confirms that optimized drip irrigation emitters have better anti clogging performance under multiple particle size drip irrigation conditions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.