Mechanical assessment of a titanium cervical spine corpectomy cage assembled with 3D-printed patient-specific endplate-conformed contact surfaces and a traditionally manufactured expandable mechanism.

Shih-Chieh Shen, Shao-Fu Huang, Wei-Hsiang Sun, Chun-Li Lin

Abstract read
In one paragraph

Article in 3D printing in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Shih-Chieh ShenDepartment of Biomedical Engineering, National Yang Ming Chaio Tung University, Taipei, Taiwan.
Shao-Fu HuangDepartment of Biomedical Engineering, National Yang Ming Chaio Tung University, Taipei, Taiwan.
Wei-Hsiang SunDepartment of Biomedical Engineering, National Yang Ming Chaio Tung University, Taipei, Taiwan.
Chun-Li LinDepartment of Biomedical Engineering, Innovation & Translation Center of Medical Device, National Yang Ming Chaio Tung University, 112, No.155, Sec. 2, Linong Street, Taipei, Taiwan. cllin2@nycu.edu.tw.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study developed a new titanium cervical spine expandable corpectomy cage (ECC) that consisted of two superior/inferior patient-specific endplate-conformed contact surfaces (PECSs) fabricated through 3D printing and a standardized centrally expandable mechanism (CEM) manufactured using traditional machining. Fatigue testing was conducted to evaluate whether the components of ECC could be assembled using different manufacturing methods to meet the functional testing requirements in compliance with FDA regulations. The titanium 3D-printed superior/inferior PECSs were designed based on the CT images/CAD system to assembly with a CNC milling/precision wire cutting cuboid CEM (14 mm square cross-section) expansion driven by a set of sliders interlocked via key and keyway mechanisms for the ECC of two-segmental vertebral bodies. The ECC underwent FDA-compliant static/dynamic compression, shear, torsion, subsidence tests and finite element (FE) analysis for understanding the stress differences on endplates between PECS and flat-shaped endplate contact surface (FECS). Stiffness/yield strength were found to be 2127 ± 146 N/mm/8547 ± 1213 N for the compression test, 1158 ± 139 N/mm/ 2561 ± 114 N for the shear test, and 1.22 ± 0.32 Nm/deg/16.5 ± 0.58 Nm for the torque test. Some failure samples showed that fixation screws were fractured/loosened under the shear test. The endure limits were 1600 N, 350 N and 1.0 N*m under compression, shear and torsion cyclic load tests, respectively. The results of the static axial compression and static/dynamic compression-shear testing did not meet the acceptance criteria of ISO 23,089. The PECS with higher stiffness value showed that better subsidence resistance was achieved than FECS and was consistent with that the maximum stress value and distribution for the FECS were more harmful than those for the PECS models. This study demonstrated that mechanical testing is essential when assembling 3D-printed components with CNC-manufactured parts in multi-component medical implants, as mismatches in interface behavior may result in mechanical failure. The results of FE analysis and subsidence tests indicated that PECS can decrease stress concentration between the ECC and endplates to present better performance for subsidence resistance.