ArticleCyborg and bionic systems (Washington, D.C.)2025
Integrated Piezoelectric Vibration and In Situ Force Sensing for Low-Trauma Tissue Penetration.
Article in Cyborg and bionic systems (Washington, D.C.), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Mitigating lateral sensing blind spots: A dual-segment bronchoscopic robot with a bioinspired skin.Science advances · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Precision-controlled microscale manipulation tasks-including neural probe implantation, ophthalmic surgery, and cell membrane puncture-often involve minimally invasive membrane penetration techniques with real-time force feedback to minimize tissue trauma. This imposes rigorous design requirements on the corresponding miniaturized instruments with robotic assistance. This paper proposes an integrated piezoelectric module (IPEM) that combines high-frequency vibration-assisted penetration with real-time in situ force sensing. The IPEM features a compact piezoelectric actuator integrated with a central tungsten probe, generating axial micro-vibration (4,652 Hz) to enable smooth tissue penetration while simultaneously measuring contact and penetration forces via the piezoelectric effect. Extensive experiments were conducted to validate the effectiveness and efficacy of the proposed IPEM. Both static and dynamic force-sensing tests demonstrate the linearity, sensitivity (9.3 mV/mN), and accuracy (mean absolute error < 0.3 mN, mean absolute percentage error < 1%) of the embedded sensing unit. In gelatin phantom tests, the module reduced puncture and insertion forces upon activation of vibration. In vivo experiments in mouse brains further confirmed that the system could reduce penetration resistance (from an average of 11.67 mN without vibration to 7.8 mN with vibration, decreased by 33%) through the pia mater and accurately mimic the electrode implantation-detachment sequence, leaving a flexible electrode embedded with minimal trauma. This work establishes a new paradigm for smart surgical instruments by integrating a compact actuator-sensor design with real-time in situ force feedback capabilities, with immediate applications in brain-machine interfaces and microsurgical robotics.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.