Evidence map›Paper›PMID 41127140›Full record

ArticleJournal of medical imaging (Bellingham, Wash.)2025

Joint CT reconstruction of anatomy and implants using a mixed prior model.

Xiao Jiang, Grace J Gang, J Webster Stayman

Abstract read
In one paragraph

Article in Journal of medical imaging (Bellingham, Wash.), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Xiao JiangJohns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States.ORCID https://orcid.org/0000-0002-5996-8070
Grace J GangUniversity of Pennsylvania, Department of Radiology, Philadelphia, Pennsylvania, United States.ORCID https://orcid.org/0000-0002-3882-0210
J Webster StaymanJohns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States.

Funding

Patient-specific, high-sensitivity spectral CT for assessment of pancreatic cancerR01EB030494 · NIBIB · UNIVERSITY OF PENNSYLVANIA · PI GANG, JIANAN GRACE, NOËL, PETER B · 2021 to 2024
$2.4M
NIBIB NIH HHS R01 EB030494
6 · The paper itself

Abstract

Purpose: Medical implants, often made of dense materials, pose significant challenges to accurate computed tomography (CT) reconstruction, especially near implants due to beam hardening and partial-volume artifacts. Moreover, diagnostics involving implants often require separate visualization for implants and anatomy. In this work, we propose a approach for joint estimation of anatomy and implants as separate volumes using a mixed prior model. Approach: We leverage a learning-based prior for anatomy and a sparsity prior for implants to decouple the two volumes. In addition, a hybrid mono-polyenergetic forward model is employed to accommodate the spectral effects of implants, and a multiresolution object model is used to achieve high-resolution implant reconstruction. The reconstruction process alternates between diffusion posterior sampling for anatomy updates and classic optimization for implants and spectral coefficients. Results: Evaluations were performed on emulated cardiac imaging with stent and spine imaging with pedicle screws. The structures of the cardiac stent with 0.25 mm wires were clearly visualized in the implant images, whereas the blooming artifacts around the stent were effectively suppressed in the anatomical reconstruction. For pedicle screws, the proposed algorithm mitigated streaking and beam-hardening artifacts in the anatomy volume, demonstrating significant improvements in SSIM and PSNR compared with frequency-splitting metal artifact reduction and model-based reconstruction on slices containing implants. Conclusion: The proposed mixed prior model coupled with a hybrid spectral and multiresolution model can help to separate spatially and spectrally distinct objects that differ from anatomical features in single-energy CT, improving both image quality and separate visualization of implants and anatomy.

Indexed as

diffusion modelimaging prior modelimplant artifact reductionmodel-based computed tomography reconstructionmultiresolution imaging

Identifiers

PMID41127140
PMCPMC12537543

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.