Evidence map›Paper›PMID 41125690›Full record

ArticleScientific reports2025

Novel heat exchanger in extracorporeal circuit: technical and biological feasibility.

Jiri Ruzicka, Filip Tichanek, Jiri Skorpil, Jiri Dejmek, Lukas Bolek, Ondrej Brzon, Richard Palek, Jachym Rosendorf, Vladimira Moulisova, Maria Stefania Massaro and 2 more

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Jiri RuzickaBiomedical Center, Faculty of Medicine in Pilsen, Charles University, Alej Svobody 76, Plzen, Czech Republic. jiri.ruzicka@lfp.cuni.cz.
Filip TichanekBiomedical Center, Faculty of Medicine in Pilsen, Charles University, Alej Svobody 76, Plzen, Czech Republic.
Jiri SkorpilBiomedical Center, Faculty of Medicine in Pilsen, Charles University, Alej Svobody 76, Plzen, Czech Republic.
Jiri DejmekBiomedical Center, Faculty of Medicine in Pilsen, Charles University, Alej Svobody 76, Plzen, Czech Republic.
Lukas BolekBiomedical Center, Faculty of Medicine in Pilsen, Charles University, Alej Svobody 76, Plzen, Czech Republic.
Ondrej BrzonBiomedical Center, Faculty of Medicine in Pilsen, Charles University, Alej Svobody 76, Plzen, Czech Republic.
Richard PalekBiomedical Center, Faculty of Medicine in Pilsen, Charles University, Alej Svobody 76, Plzen, Czech Republic.
Jachym RosendorfBiomedical Center, Faculty of Medicine in Pilsen, Charles University, Alej Svobody 76, Plzen, Czech Republic.
Vladimira MoulisovaBiomedical Center, Faculty of Medicine in Pilsen, Charles University, Alej Svobody 76, Plzen, Czech Republic.
Maria Stefania MassaroBiomedical Center, Faculty of Medicine in Pilsen, Charles University, Alej Svobody 76, Plzen, Czech Republic.
Václav LiskaBiomedical Center, Faculty of Medicine in Pilsen, Charles University, Alej Svobody 76, Plzen, Czech Republic.
Jitka KuncovaBiomedical Center, Faculty of Medicine in Pilsen, Charles University, Alej Svobody 76, Plzen, Czech Republic.

Funding

European Regional Development Fund CZ.02.1.01/0.0/0.0/16_019/0000787Univerzita Karlova v Praze 207043
6 · The paper itself

Abstract

To evaluate a novel anticoagulation strategy in an extracorporeal circuit, we introduce a device that induces local hypothermia as blood flows through the circuit. Using a pig model, we assessed its technical feasibility, biocompatibility, and safety. Sixteen pigs were randomly assigned to either the cooled group or the control group and underwent midline laparotomy to establish extracorporeal circulation (blood flow 500 ml/min) via the caudal vena cava for up to four hours. Blood samples were collected at baseline and at 15, 60, and 240 min during the experiment. In the cooled group, blood was cooled to 20 °C and then rewarmed to 37 °C, while in the control group, blood was maintained at 37 °C. A total of 6 cooled and 4 control pigs completed 4 h of the experiment. Our findings confirm the technical feasibility of the proposed device, which effectively maintained the required temperature differentials while keeping the pressure differentials in the circuit within 150 mmHg. No issues with circuit patency were observed. Additionally, no adverse effects were detected on erythrocyte stability. Within the limitation of the short observation period, no adverse effects were observed on renal, liver, or cardiac function. Our data suggest that local hypothermia in the extracorporeal circuit may mitigate surgery-induced inflammation.

Indexed as

Extracorporeal CirculationHypothermia, InducedAnimalsFeasibility StudiesSwineBiocompatibilityCoagulationExtracorporeal circuitHypothermiaInflammation

Identifiers

PMID41125690
PMCPMC12546831

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.