Evidence map›Paper›PMID 41125663›Full record

ArticleScientific reports2025

Accuracy of saliva tests for SARS-CoV-2 diagnosis during the pandemic in Rio de Janeiro, Brazil.

Rebecca Fiorani-Nascimento, Kethely Lima Marques, Victor Jardim de Carvalho, Felipe Pessoa Dias, Julia Magalhães Cabral, Cesar Werneck Noce Dos Santos, Marcelo Rolla de Souza, Carolina Mendes Franco, Flávia Alvim Dutra de Freitas, André Candéa and 3 more

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Rebecca Fiorani-NascimentoFederal University of the State of Rio de Janeiro, Rio de Janeiro, Brazil. rebeccafiorani@yahoo.com.br.
Kethely Lima MarquesOswaldo Cruz Foundation, Rio de Janeiro, Brazil.
Victor Jardim de CarvalhoOswaldo Cruz Foundation, Rio de Janeiro, Brazil.
Felipe Pessoa DiasFederal University of the State of Rio de Janeiro, Rio de Janeiro, Brazil.
Julia Magalhães CabralFederal University of the State of Rio de Janeiro, Rio de Janeiro, Brazil.
Cesar Werneck Noce Dos SantosBrazilian Air Force, Rio de Janeiro, Brazil.
Marcelo Rolla de SouzaBrazilian Air Force, Rio de Janeiro, Brazil.
Carolina Mendes FrancoOswaldo Cruz Foundation, Rio de Janeiro, Brazil.
Flávia Alvim Dutra de FreitasOswaldo Cruz Foundation, Rio de Janeiro, Brazil.
André CandéaOswaldo Cruz Foundation, Rio de Janeiro, Brazil.
Erika Martins de CarvalhoOswaldo Cruz Foundation, Rio de Janeiro, Brazil.
Marcelo Ribeiro-AlvesOswaldo Cruz Foundation, Rio de Janeiro, Brazil.
Rodolfo CastroFederal University of the State of Rio de Janeiro, Rio de Janeiro, Brazil. rodolfo.castro@fiocruz.br.

Funding

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior Programa de Demanda Social / PPGBMC UNIRIOPrograma Inova Fiocruz/Fundação Oswaldo Cruz 48111533445761
6 · The paper itself

Abstract

Saliva is a promising non-invasive alternative to nasopharyngeal swabs (NPS) for SARS-CoV-2 diagnosis, yet its longitudinal performance remains underexplored. This longitudinal study evaluated saliva's diagnostic accuracy against NPS in 72 symptomatic individuals across six visits (July 2021-May 2022), analyzing 285 paired RT-qPCR samples in Rio de Janeiro, Brazil. Using NPS as the reference standard, saliva demonstrated high specificity (96.6%; 95% CI 92.9-98.7%), substantial agreement (91.6%; κ = 0.78; 95% CI 70-86% ; P < 0.001), and variable sensitivity (69.2% overall; 95% CI 57.2-79.5%), ranging from 40% during mid-phase infection (visit 3) to 82% during early infection (visit 1). Cycle threshold (Ct) values revealed slightly higher viral loads in NPS (mean Ct = 26.75) than in saliva (mean Ct = 28.75), with a mean difference of 0.79 cycles. Discordant results (8.4%) revealed saliva's utility in detecting late-stage infections missed by NPS. No significant associations were found between diagnostic agreement and participant characteristics or Ct values. In conclusion, our longitudinal data demonstrate that saliva testing achieves 69.2% sensitivity (ranging from 40 to 82% across infection phases), 96.6% specificity, and 91.6% overall agreement with NPS. The 8.4% discordant results included 1.7% of cases where saliva-detected infections were missed by NPS, highlighting its complementary value in late-stage monitoring. These results, coupled with saliva's stability over time, support its implementation as a scalable, cost-effective diagnostic tool-particularly in resource-limited settings-where its high specificity makes it particularly valuable for rule-out testing despite temporal variations in sensitivity.

Indexed as

COVID-19COVID-19 TestingSalivaSARS-CoV-2AdolescentAdultAgedBrazilCOVID-19 Nucleic Acid TestingFemaleHumansLongitudinal StudiesMaleMiddle AgedNasopharynxPandemicsCOVID-19 testingInfectious-disease diagnosticsResource-limited settingsSaliva testingSARS-CoV-2Temporal diagnostic accuracyViral shedding kinetics

Identifiers

PMID41125663
PMCPMC12546890

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.