ArticleScientific reports2025
Robust load frequency control in renewable integrated Multi Area grids using hybrid SA and QIO tuned PIDF controller.
Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Optimal control of a heat flow system via novel enhanced quadratic interpolation optimization tuned 2DOF-PID controller.Scientific reports · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Frequency stability in renewable-integrated power systems faces critical challenges from load fluctuations, solar/wind intermittency, and nonlinear dynamics. Conventional Proportional-Integral-Derivative (PID) controllers exhibit poor disturbance rejection during concurrent solar irradiance drops and load steps, while optimization algorithms like Genetic Algorithm (GA), Particle Swarm Optimization (PSO), Artificial Neural Network (ANN), and Support Vector Machine (SVM) controllers suffer from premature convergence or computational inefficiency. To address this, we propose a hybrid Simulated Annealing-Quadratic Interpolation Optimizer (hsa-QIO)-tuned filtered PID (PID-F) controller for robust load frequency control in two-area grids with wind, photovoltaic (PV), and thermal generation. The hsa-QIO synergizes global exploration (quadratic interpolation) and probabilistic refinement (simulated annealing), overcoming solution space stagnation. Validated through MATLAB/Simulink simulations under dynamic solar irradiance fluctuations and random load perturbations (0.1-0.4 pu), our approach achieves: 55.7% reduction in Integral Time-weighted Absolute Error (ITAE) versus QIO; 25% lower overshoot (0.9% vs. ANN-PID's 1.2%) and 50% faster settling (0.1 s vs. GA-PID's 0.2 s) in Area 1; superior tie-line regulation (0.3% overshoot/0.4% undershoot vs. SVM's 0.5% and PSO-PID's 0.8%); and statistical robustness with 98.8% lower ITAE deviation (σ = 0.010578) across 30 runs. This computationally efficient solution enables stringent frequency stability (± 0.2 Hz) in high-renewable penetration grids.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.