Evidence map›Paper›PMID 41124154›Full record

ArticlePloS one2025

Development of a new cell isolation device FlowMagicTM.

Tomoyuki Yoshida, Yoshiaki Sakamoto, Aya Tsuruta, Risa Kimura, Nozomi Shiozawa, Takeyuki Kotaka

Abstract read
In one paragraph

Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Trial
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Tomoyuki YoshidaH.U. Group Research Institute G.K., Akiruno, Tokyo, Japan.ORCID https://orcid.org/0009-0000-9060-6206
Yoshiaki SakamotoH.U. Group Research Institute G.K., Akiruno, Tokyo, Japan.
Aya TsurutaH.U. Group Research Institute G.K., Akiruno, Tokyo, Japan.
Risa KimuraH.U. Group Research Institute G.K., Akiruno, Tokyo, Japan.
Nozomi ShiozawaH.U. Cells, Inc., Akiruno, Tokyo, Japan.
Takeyuki KotakaH.U. Group Research Institute G.K., Akiruno, Tokyo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Isolation of human peripheral blood mononuclear cells (PBMCs) from blood typically involves a density gradient medium during density centrifugation. The problem of increasing red blood cell (RBC) and granulocyte (GRA) contamination during PBMC isolation as the elapsed time after blood collection increases remains unresolved. As a countermeasure against RBC contamination, hemolysis treatment is available; however, these extra steps are laborious, time-consuming, and could introduce artifacts. To overcome this challenge, we developed a novel isolation device, FlowMagic™, which features a proprietary two-layer insert structure designed to prevent RBC and GRA contamination during PBMC isolation from blood. The efficacy of this method was evaluated by isolating PBMCs from donors and analyzing immune cell populations by flow cytometry. Compared to SepMate (median (Q50) = 11.0, interquartile ranges (IQR): 8.8-19.5; p < 0.01) and Lymphoprep methods (Q50 = 9.3, IQR: 6.6-13.5; p < 0.01), FlowMagic™ achieved significantly greater reduction in RBC contamination to below detectable limits (Q50 = 0.0, IQR: 0.0-0.0), with sustained efficacy observed up to 72 hours post-collection. Additionally, the FlowMagic™ method (Q50 = 2.5, IQR: 0.5-3.4, at 48 hours, median = 4.5, IQR: 2.1-10.3, at 72 hours, respectively) significantly reduced GRA contamination compared with the SepMate (Q50 = 12.0, IQR: 7.8-25.5, at 48 hours, Q50 = 27.5, IQR: 12.3-29.0, at 72 hours, respectively; p < 0.01) and Lymphoprep methods (Q50 = 10.5, IQR: 6.9-19.8, at 48 hours, Q50 = 17.5, IQR: 13.3-23.5, at 72 hours, respectively; p < 0.01) at 48 and 72 hours after blood collection. Furthermore, the recovery rates of CD3 + , CD4 + , CD8 + , CD19 + , and CD16/56 + cells in the FlowMagic™-isolated PBMCs (Q50 = 8.6, 5.9, 2.5, 1.3, and 1.9, respectively) were significantly improved compared to those in SepMate- (Q50 = 2.2, 1.5, 0.7, 0.4, and 0.5, respectively; p < 0.01) and Lymphoprep-isolated PBMCs (Q50 = 2.4, 1.5, 0.8, 0.6, and 0.8, respectively; p < 0.01), even at 48 hours after blood collection. These findings suggest that the PBMC isolation method using FlowMagic™ is advantageous in preventing RBC and GRA contamination for research, diagnostic, and clinical applications.

Indexed as

Cell SeparationLeukocytes, MononuclearErythrocytesFlow CytometryGranulocytesHumans

Identifiers

PMID41124154
PMCPMC12543197

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.