Evidence map›Paper›PMID 41122259›Full record

Trial reportGhana medical journal2025

Agreement between intraocular pressure measurement using Goldmann applanation tonometry with and without fluorescein in consecutive Ghanaian patients.

Charles Darko-Takyi, Youfegan B Mathurin, Emmanuel Essien, Sandra Owusu, Osei A Yaw, Kwame O Osei, Selina Holdbrook, Andrew Owusu-Ansah

Abstract readRandomized Controlled Trial
In one paragraph

Trial report in Ghana medical journal, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Charles Darko-TakyiSchool of Optometry and Vision Science, College of Health and Allied Sciences, University of Cape Coast, Ghana.
Youfegan B MathurinUniversity of Cape Coast Eye Clinic, Cape Coast, Ghana.
Emmanuel EssienSchool of Optometry and Vision Science, College of Health and Allied Sciences, University of Cape Coast, Ghana.
Sandra OwusuSchool of Optometry and Vision Science, College of Health and Allied Sciences, University of Cape Coast, Ghana.
Osei A YawOur Lady of Grace Catholic Mission Hospital, Bremen Esikuma, Ghana.
Kwame O OseiKorle-Bu Teaching Hospital Eye Centre, Accra, Ghana.
Selina HoldbrookSchool of Optometry and Vision Science, College of Health and Allied Sciences, University of Cape Coast, Ghana.
Andrew Owusu-AnsahSchool of Optometry and Vision Science, College of Health and Allied Sciences, University of Cape Coast, Ghana.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: The interchangeability of Goldmann Applanation Tonometry (GAT) with or without fluorescein requires clarification among African populations. The present study aimed to determine the agreement between IOP measurement using GAT with and without fluorescein in consecutive patients in Ghana. Design: A prospective cross-sectional clinic-based study design. Setting: The study was conducted at the Ophthalmology and Optometry units of the UCC Eye Clinic, Cape Coast, Ghana. Participants: A convenient sample of 104 consecutive patients who visited the clinic. The participants were randomised into two groups, where those in the first had their IOPs first measured without fluorescein and later with fluorescein on GAT; participants in the second group had their IOPs first measured with fluorescein and later without fluorescein after a 10-minute washout period. The central corneal thickness was measured using the Anterior Segment model of Zeiss Cirrus HD-OCT. Results: There was no agreement between the unadjusted IOP measures with and without fluorescein with GAT using the Bland Altman analysis (p < 0.0001, Lower limit: -0.9433, Upper limit: 6.8914; 95% CI = -1.6097 to -.02769). There were no statistically significant differences in gender between unadjusted IOP measurements with (Mann Whitney U test, p = 0.110) and without (Mann-Whitney U test, p = 0.083) fluorescein. Conclusion: Unadjusted IOP measurement without fluorescein was approximately 3 mmHg significantly lower than with fluorescein. We recommend practitioners maintain the gold standard GAT with fluorescein to guide accurate glaucoma diagnosis and management decision-making. Funding: Self-funded.

Indexed as

FluoresceinGlaucomaIntraocular PressureTonometry, OcularAdultAgedCross-Sectional StudiesFemaleGhanaHumansMaleMiddle AgedProspective StudiesReproducibility of ResultsFluoresceinGhanaian patientsGoldmann Applanation TonometryIntraocular PressureWith fluoresceinWithout Fluorescein

Identifiers

PMID41122259
PMCPMC12536567

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.