Evidence map›Paper›PMID 41121354›Full record

ArticleJournal of neuroengineering and rehabilitation2025

AI-based patient monitoring for fall prevention in stroke patients: a pilot study at a Malaysian acute stroke unit.

Monica Danial, Chee Toong Chow, Meng Hui Lim, Noor Azleen Ayop, Irene Looi, Alan Swee Hock Ch'ng

Abstract read
In one paragraph

Article in Journal of neuroengineering and rehabilitation, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Monica DanialClinical Research Centre (CRC) Hospital Seberang Jaya, Institute for Clinical Research, Ministry of Health Malaysia (MOH), Seberang Jaya, Penang, Malaysia. monicadanial83@gmail.com.
Chee Toong ChowDepartment of Emergency and Trauma Hospital Seberang Jaya, Ministry of Health Malaysia (MOH), Seberang Jaya, Penang, Malaysia.
Meng Hui LimSmartPeep Pte Ltd, Singapore, Singapore.
Noor Azleen AyopDepartment of Emergency and Trauma Hospital Seberang Jaya, Ministry of Health Malaysia (MOH), Seberang Jaya, Penang, Malaysia.
Irene LooiMedical Department, Hospital Seberang Jaya, Ministry of Health Malaysia (MOH), Seberang Jaya, Penang, Malaysia.
Alan Swee Hock Ch'ngMedical Department, Hospital Seberang Jaya, Ministry of Health Malaysia (MOH), Seberang Jaya, Penang, Malaysia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFalls are an important patient safety concern and stroke patient are at high risk. Artificial intelligence (AI) could be leveraged to reduce patient falls in the hospital but there is scarcity of data. Therefore, the aim of this study is to evaluate the effectiveness of the SMART AI Patient Sitter system-an AI-powered motion-sensing and alert system designed for fall detection and prevention in a real-world hospital setting.

methodsConducted from January to December 2024 at the Acute Stroke Unit of Hospital Seberang Jaya (ASUHSJ), the study involved 30 stroke patients who consented to AI monitoring. The SMART AI patient sitter system comprised an optical sensor, alert panel, and control panel monitored by AI, which detected patient movement and triggered alerts to the observation counter. Blurred, non-identifiable images maintained patient privacy, and investigators were identified through uniform recognition. Data on mobility and fall events were recorded continuously.

resultsThe integration of this system led to an 83.33% reduction in fall incidents and the generation of 1,439 alerts with a 95.34% accuracy rate. Enrolled patients had a mean age of 61 years(SD ± 12.8) years; 63.3% were male; 56.7% were of Malay ethnicity and 83.3% were classified as high fall risk. The median duration of monitoring was 3 days (IQR: 1.0-6.0), with a median of 19 bed exits(IQR: 1.0-85.0) bed exits. The first bed exit attempt occurred at a median of 150 minutes (IQR: 20.0-2103.0) minutes post-admission. Response time to movement alerts was prompt, with a median of 21  seconds (IQR: 4.0-75.0). Only one fall (3.3%) was recorded during the study. The incident involved a moderate-risk patient who attempted to stand abruptly. Staff responded within 29 seconds, and the patient recovered without severe injury.

conclusionThese findings suggest the system's potential in early detection and timely intervention. Study data demonstrated wide variability in patient mobility patterns, highlighting the need for individualized monitoring. The SMART AI patient sitter system's ability to deliver real-time alerts, ensure patient privacy, and reduce fall incidence demonstrates its value in improving stroke patient safety. Overall, this study supports the integration of AI-based monitoring tools in clinical settings to enhance patient care and reduce preventable incidents like falls.

Indexed as

Accidental FallsArtificial IntelligenceStrokeStroke RehabilitationAgedFemaleHumansMalaysiaMaleMiddle AgedMonitoring, PhysiologicPilot ProjectsAI-based monitoringFallHospitalized patientsSMART AI patient sitter systemStroke

Identifiers

PMID41121354
PMCPMC12542081

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.