Evidence map›Paper›PMID 41117919›Full record

ArticleMikrochimica acta2025

Comparative investigation into flexible alginate-based hydrogel sponges with excellent biocompatibility and breathability for reliable strain and pressure sensors.

Yu Fu, Shun Peng, Zhenshuai Wan, Yibin Fan, Peng Liu, Ronghan Wei

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Mikrochimica acta, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yu FuSchool of Mechanics and Safety Engineering, Zhengzhou University, Zhengzhou, 450001, PR China.ORCID 0000-0002-6478-9149
Shun PengSchool of Mechanical and Electrical Engineering, Henan University of Technology, Zhengzhou, 450001, PR China.
Zhenshuai WanSchool of Mechanical and Electrical Engineering, Henan University of Technology, Zhengzhou, 450001, PR China. wanzhenshuai@haut.edu.cn.ORCID 0000-0001-9114-2634
Yibin FanSchool of Mechanical and Electrical Engineering, Henan University of Technology, Zhengzhou, 450001, PR China.
Peng LiuSchool of Mechanical and Electrical Engineering, Henan University of Technology, Zhengzhou, 450001, PR China.
Ronghan WeiSchool of Mechanics and Safety Engineering, Zhengzhou University, Zhengzhou, 450001, PR China. profwei@zzu.edu.cn.

Funding

National Natural Science Foundation of China 52505599the Cultivation Project of Tuoxin Team in Henan University of Technology 2024TXTD16the Key Science and Technology Project of Henan Province 252102221048the Undergraduate Innovation Training Program Project in Henan University of Technology 202510463044the Undergraduate Research Training Program in Henan University of Technology KYXL2025021the Undergraduate Research Training Program in Henan University of Technology KYXL2025022
6 · The paper itself

Abstract

Flexible sensors with a porous hydrogel structure have attracted enormous attention for their extensive potential prospects in the fields of wearable electronics and human-machine interaction (HMI). Nevertheless, these sensors encounter significant challenges in synchronously achieving breathability, favorable biocompatibility, and high strain/pressure sensitivity. Herein, various sodium alginate (SA)-based hydrogel sponges are prepared by a facile one-pot and directional freezing process for comparative studies. The obvious oriented and uniform pore structures can provide a spatial anisotropy dispersion framework for the conductive fillers, and the effective connectivity among these interface structures facilitates the rapid deformation and recovery of the entire structure. Compared to other hydrogel sponges, the SA/silk fibroin (SF) hydrogel sponge demonstrates a more consistent pore distribution, preferable size uniformity, mechanical strength, deformation capability, and porosity properties. The designed SA/SF-based strain sensor with a satisfied gauge factor of 1.69 and durability can precisely monitor the physiological signals produced by humans. It exhibits favorable pressure sensitivity (- 1.10 kPa

Indexed as

AlginatesBiocompatible MaterialsHydrogelsWearable Electronic DevicesFibroinsHumansPorosityPressureAlginatesBiocompatible MaterialsFibroinsHydrogelsAlginate-based hydrogel spongeBreathabilityDeep learning modelFlexible strain and pressure sensorInformation encoding

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.