Evidence map›Paper›PMID 41116853›Full record

ArticleGastroenterology and hepatology from bed to bench2025

Design and optimization of a multiplex real-time PCR assay for detection of Hepatitis C virus (HCV), Human immunodeficiency virus-1 (HIV-1) and Human hepegivirus-1 (HHpgV-1).

Paria Pirasteh, Seyed Reza Mohebbi, Seyed Masoud Hosseini, Shabnam Kazemian, Amir Ghaemi, Abolfazl Fateh, Mohammad Reza Zali

Abstract read
In one paragraph

Article in Gastroenterology and hepatology from bed to bench, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Paria PirastehBasic and Molecular Epidemiology of Gastrointestinal Disorders Research Center, Research Institute for Gastroenterology and Liver Diseases, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Seyed Reza MohebbiResearch Center for Gastroenterology and Liver Diseases, Research Institute for Gastroenterology and Liver Diseases, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Seyed Masoud HosseiniDepartment of Microbiology and Microbial Biotechnology, Faculty of Life Sciences and Biotechnology, Shahid Beheshti University, Tehran, Iran.
Shabnam KazemianResearch Center for Gastroenterology and Liver Diseases, Research Institute for Gastroenterology and Liver Diseases, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Amir GhaemiDepartment of Virology, Pasteur Institute of Iran, Tehran, Iran.
Abolfazl FatehDepartment of Mycobacteriology and Pulmonary Research, Pasteur Institute of Iran, Tehran, Iran.
Mohammad Reza ZaliResearch Center for Gastroenterology and Liver Diseases, Research Institute for Gastroenterology and Liver Diseases, Shahid Beheshti University of Medical Sciences, Tehran, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aim: The objective of this study was to develop a real-time PCR method to detect hepatitis C virus (HCV), human immunodeficiency virus-1 (HIV-1), and also recently discovered human hepegivirus-1 (HHpgV-1) through melting curve analysis using SYBR Green dye in a single reaction. Background: It is estimated that chronic viral infections affect millions of people worldwide, and a significant number of these individuals are unaware of their infection. In addition, infection with newly discovered and emerging viruses may put public health at potential risks. Precise and early detection is a primary and important task for controlling infections and helping patients. Methods: A set of specific primers were designed for detection of HCV, HIV-1, and HHpgV-1 in a single tube. The real-time polymerase chain reaction was performed and melt curves were analyzed. Specificity was assessed by cross-reaction tests with other common blood-borne pathogens. The established assay was evaluated for the detection of viruses in clinical samples. Results: The three viruses were clearly distinguished by their respective melting temperature values. The detection limits of this assay were 10 Conclusion: The developed multiplex real-time PCR based on SYBR Green dye is a well-suited detection assay of single or co-infections of HCV, HIV, and HHpgV-1 in clinical and research laboratories. It can be used as a cost-effective, rapid tool for routine diagnostic in-house tests.

Indexed as

Co-infectionHepatitis C virusHuman hepegivirus-1Human immunodeficiency virusMultiplex polymerase chain reactionReal-time polymerase chain reactionSYBR green

Identifiers

PMID41116853
PMCPMC12535783

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.