Evidence map›Paper›PMID 41115923›Full record

ArticleScientific reports2025

Formaldehyde vapour fixation enables multiscale phase-contrast imaging and histological validation of human-sized lungs.

Christian Dullin, Johanna Reiser, Willi L Wagner, Elena Longo, Marko Prašek, Adriano Contillo, Nicola Sodini, Diego Dreossi, Paola Confalonieri, Francesco Salton and 17 more

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

27 authors.

Christian Dullin *Department of Clinical and Interventional Radiology, University Medical Center Goettingen, Goettingen, Germany. christian.dullin@protonmail.com.
Johanna Reiser *Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany.
Willi L WagnerDepartment of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany.
Elena LongoElettra-Sincrotrone Trieste S.C.p.A., Basovizza, Italy.
Marko PrašekElettra-Sincrotrone Trieste S.C.p.A., Basovizza, Italy.
Adriano ContilloElettra-Sincrotrone Trieste S.C.p.A., Basovizza, Italy.
Nicola SodiniElettra-Sincrotrone Trieste S.C.p.A., Basovizza, Italy.
Diego DreossiElettra-Sincrotrone Trieste S.C.p.A., Basovizza, Italy.
Paola ConfalonieriDepartment of Pulmonology, University Hospital of Cattinara, Trieste, Italy.
Francesco SaltonDepartment of Pulmonology, University Hospital of Cattinara, Trieste, Italy.
Marco ConfalonieriDepartment of Pulmonology, University Hospital of Cattinara, Trieste, Italy.
Elisa BaratellaDepartment of Radiology, University Hospital of Cattinara, Trieste, Italy.
Maria Assunta CovaDepartment of Radiology, University Hospital of Cattinara, Trieste, Italy.
Claudia V BenkeDepartment of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany.
Md Motiur Rahman SagarTranslational Molecular Imaging, Max-Planck-Institute for Multidisciplinary Sciences, Goettingen, Germany.
Lorenzo D'AmicoElettra-Sincrotrone Trieste S.C.p.A., Basovizza, Italy.
Jonas AlbersEuropean Molecular Biology Laboratory (EMBL), Hamburg Unit c/oDESY, Hamburg, Germany.
Angelika SvetloveEuropean Molecular Biology Laboratory (EMBL), Hamburg Unit c/oDESY, Hamburg, Germany.
Elizabeth DukeEuropean Molecular Biology Laboratory (EMBL), Hamburg Unit c/oDESY, Hamburg, Germany.
Tatiana FlisikowskaDepartment of Molecular Life Sciences, Chair of Livestock Biotechnology, School of Life Sciences Weihenstephan, Technical University of Munich, Freising, Germany.
Krzysztof FlisikowskiDepartment of Molecular Life Sciences, Chair of Livestock Biotechnology, School of Life Sciences Weihenstephan, Technical University of Munich, Freising, Germany.
Mark O WielpützDepartment of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany.
Jürgen BiedererDepartment of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany.
Hans-Ulrich KauczorDepartment of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany.
Frauke AlvesDepartment of Clinical and Interventional Radiology, University Medical Center Goettingen, Goettingen, Germany.
Fabrizio ZanconatiDepartment of Medical, Surgical and Health Sciences, University Hospital of Cattinara, Trieste, Italy.
Giuliana TrombaElettra-Sincrotrone Trieste S.C.p.A., Basovizza, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Accurate diagnosis and characterization of lung disease increasingly rely on advanced imaging modalities capable of resolving fine microstructural details while minimizing radiation exposure. Phase-sensitive computed tomography (CT), particularly propagation-based imaging (PBI), offers superior soft tissue contrast but has historically been limited by the lack of compatible fixation techniques that preserve lung architecture post-excision. We present an adapted formaldehyde (FA) vapour fixation protocol designed to maintain human-sized lungs in a physiologically inflated and morphologically stable state. This approach prevents collapse of the delicate air-tissue interfaces, a major barrier to high-fidelity phase-contrast imaging and histological correlation. Our method enables high-resolution, multiscale imaging from whole-organ PBI at 67 µm voxel size to localized subcellular synchrotron PBI at 650 nm voxel size on the same specimen, with preserved spatial relationships critical for accurate validation of imaging findings. In porcine models, FA vapour fixation maintained alveolar integrity and radiological contrast without compromising histological detail, while also avoiding the artifacts associated with liquid fixation. Crucially, the protocol allows regulation of inflation and fixation dynamics, addressing longstanding challenges in ex vivo lung imaging and enabling consistent specimen preparation across studies. This fixation technique supports biosafe stabilization of freshly explanted human lungs-such as those from transplant procedures creating new opportunities for translational research on pathological tissue. By bridging high-resolution radiology and histopathology, our scalable fixation protocol establishes a standardized foundation for multimodal lung imaging and offers a critical tool for advancing both fundamental lung research and clinical diagnostics.

Indexed as

FormaldehydeLungTissue FixationAnimalsFixativesHumansSwineTomography, X-Ray ComputedFixativesFormaldehydeLung imagingPhase contrastVapour fixation

Identifiers

PMID41115923
PMCPMC12537873

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.