ArticleIEEE transactions on bio-medical engineering2026
A Hybrid Sparse Primary Sampling (SPS) Strategy for CBCT.
Article in IEEE transactions on bio-medical engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Cone Beam Computed Tomography (CBCT) image quality is degraded by the increased scatter from the broad beam geometry, while conventional anti-scatter grid (ASG) only provides partial mitigation at the cost of elevated imaging dose.
objectiveIn this study, we exploit the smooth behavior of the scatter signal with a novel sparse anti-scatter grid to improve the image quality of CBCT.
methodsWe achieve sparse sampling of the primary beam signal by sparsely inserting individual collimators focusing on the X-ray source into a template in front of the detector. The novel sparse primary sampling (SPS) grid is evaluated via Monte Carlo simulations with a synthetic CT phantom, patient head phantom, and patient pelvis phantom. Image reconstruction based on SPS was formulated as a constrained optimization problem with fidelity terms on the total signal and the sparsely sampled primary signals. Image quality improvement was benchmarked using ideal primary signal reconstructed images, worst-case scatter degraded reconstructed images, and the previously studied 3-D Richardson-Lucy fitting scatter correction method using low count Monte Carlo.
resultsThe novel SPS grid and reconstruction method demonstrated recovery of HU values and image resolution with sampling densities under 0.1%.
conclusionThe hybrid hardware-software method supports flexible sampling density and pattern with minimal primary signal loss and image dose increase. SIGNIFICANCE: A novel SPS grid was introduced, and a successful demonstration in the Monte Carlo study shows the feasibility of significantly improving CBCT image quality for interventional and radiotherapy procedures via the SPS strategy.