Evidence map›Paper›PMID 41115082›Full record

ArticleIEEE transactions on bio-medical engineering2026

A Hybrid Sparse Primary Sampling (SPS) Strategy for CBCT.

Alan R Li, Qihui M Lyu, Shusen Jing, Hengjie Liu, Catherine H Frank, Lu Jiang, Dan Ruan, Ke Sheng

Abstract read
In one paragraph

Article in IEEE transactions on bio-medical engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Alan R Li
Qihui M Lyu
Shusen Jing
Hengjie Liu
Catherine H Frank
Lu Jiang
Dan Ruan
Ke Sheng

Funding

Development of a versatile robotic radiation therapy systemR44CA183390 · NCI · RADIABEAM TECHNOLOGIES, LLC · PI SHENG, KE, YONEMOTO, JAY · 2017 to 2024
$5.8M
Development of an ultra-high dose rate rotational linac for FLASH RadiotherapyR01CA255432 · NCI · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI AGUSTSSON, RONALD, SHENG, KE · 2021 to 2025
$3.2M
Precision breast radiotherapy with the soft robot and supine CTR01EB031577 · NIBIB · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI JIN, LIHUA, SHENG, KE · 2022 to 2025
$1.5M
NCI NIH HHS R01 CA255432NCI NIH HHS R44 CA183390NIBIB NIH HHS R01 EB031577
6 · The paper itself

Abstract

Cone Beam Computed Tomography (CBCT) image quality is degraded by the increased scatter from the broad beam geometry, while conventional anti-scatter grid (ASG) only provides partial mitigation at the cost of elevated imaging dose.

objectiveIn this study, we exploit the smooth behavior of the scatter signal with a novel sparse anti-scatter grid to improve the image quality of CBCT.

methodsWe achieve sparse sampling of the primary beam signal by sparsely inserting individual collimators focusing on the X-ray source into a template in front of the detector. The novel sparse primary sampling (SPS) grid is evaluated via Monte Carlo simulations with a synthetic CT phantom, patient head phantom, and patient pelvis phantom. Image reconstruction based on SPS was formulated as a constrained optimization problem with fidelity terms on the total signal and the sparsely sampled primary signals. Image quality improvement was benchmarked using ideal primary signal reconstructed images, worst-case scatter degraded reconstructed images, and the previously studied 3-D Richardson-Lucy fitting scatter correction method using low count Monte Carlo.

resultsThe novel SPS grid and reconstruction method demonstrated recovery of HU values and image resolution with sampling densities under 0.1%.

conclusionThe hybrid hardware-software method supports flexible sampling density and pattern with minimal primary signal loss and image dose increase. SIGNIFICANCE: A novel SPS grid was introduced, and a successful demonstration in the Monte Carlo study shows the feasibility of significantly improving CBCT image quality for interventional and radiotherapy procedures via the SPS strategy.

Indexed as

Cone-Beam Computed TomographyImage Processing, Computer-AssistedAlgorithmsComputer SimulationHeadHumansMonte Carlo MethodPelvisPhantoms, Imaging

Identifiers

PMID41115082
PMCPMC13456084

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.