Evidence map›Paper›PMID 41114327›Full record

ArticlePostepy w kardiologii interwencyjnej = Advances in interventional cardiology2025

Patient radiation dose and contrast usage impacted by assisted coronary angiography technologies: fractional flow reserve, instantaneous wave-free ratio, intravascular ultrasonography, and optical coherence tomography.

Christos N Bousis, Pavlos Karanikis, Thanasis Kosovitsas, Anna Kotsia, Eleni Tzima, Evaggelia Kalampoki, Polyxeni Oikonomou, Evgenia Pappa

Abstract read
In one paragraph

Article in Postepy w kardiologii interwencyjnej = Advances in interventional cardiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Christos N BousisDepartment of Medical Physics, General Hospital of Ioannina "CHATZIKOSTA", Ioannina, Greece.
Pavlos KaranikisCardiology Clinics, Haemodynamics Laboratory, General Hospital of Ioannina "CHATZIKOSTA", Ioannina, Greece.
Thanasis KosovitsasCardiology Clinics, Haemodynamics Laboratory, General Hospital of Ioannina "CHATZIKOSTA", Ioannina, Greece.
Anna KotsiaCardiology Clinics, Haemodynamics Laboratory, General Hospital of Ioannina "CHATZIKOSTA", Ioannina, Greece.
Eleni TzimaCardiology Clinics, Haemodynamics Laboratory, General Hospital of Ioannina "CHATZIKOSTA", Ioannina, Greece.
Evaggelia KalampokiCardiology Clinics, Haemodynamics Laboratory, General Hospital of Ioannina "CHATZIKOSTA", Ioannina, Greece.
Polyxeni OikonomouCardiology Clinics, Haemodynamics Laboratory, General Hospital of Ioannina "CHATZIKOSTA", Ioannina, Greece.
Evgenia PappaCardiology Clinics, Haemodynamics Laboratory, General Hospital of Ioannina "CHATZIKOSTA", Ioannina, Greece.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Although coronary angiography adjunctive technologies (AT) provide valuable insights into lesion severity and characteristics, their use increases radiation and contrast exposure. Aim: To assess the impact of AT on patients' radiation dose, irradiation and procedural times, and contrast usage. Material and methods: Dose-area product (DAP), patient effective dose, irradiation and procedural times, and contrast usage were compared between two groups, each comprising 258 patients who underwent coronary angiography with AT (AT group) or without (NoAT group). Multivariate analysis was performed on the whole patient group and the AT group to identify significant predictors of elevated DAP and contrast. Results: Compared to the NoAT group, DAP, patient effective dose, and contrast usage increased by 70-73%, while irradiation and procedural times were 120% and ~135% longer, respectively, in the AT group. Whole patient group analysis revealed that AT use was the strongest predictor of increased DAP and contrast usage (1.7; 95% CI: 1.6-1.8; Conclusions: In real-world clinical settings, the use of AT led to significant increases in patients' radiation dose, irradiation and procedural times, and contrast usage.

Indexed as

adjunctive technologiesanalysiscontrast usagedose-area product

Identifiers

PMID41114327
PMCPMC12530096

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.