Evidence map›Paper›PMID 41113782›Full record

ArticleInternational journal of clinical pediatric dentistry2025

The Impact of Thermocycling on the Marginal Discrepancy of Zirconia CAD/CAM Generation on Central Incisors: An

Abdulkarim H Alshehri

Abstract read
In one paragraph

Article in International journal of clinical pediatric dentistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Abdulkarim H AlshehriDepartment of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan, Saudi Arabia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Zirconia ceramic materials have become a preferred choice for anterior teeth, but their marginal performance under thermocycling has not been sufficiently investigated. Thus, this Materials and methods: A total of 36 zirconia central incisor crowns were fabricated using three different CAD/CAM systems (ZirCAD Prime, Cercon ht ML, Zolid Bion; 12 per group) and cemented onto models made from resin. After aging for 48 hours in artificial saline, the crowns underwent thermocycling for 10,000 cycles. Marginal discrepancies were measured at two points on four sides per specimen under a digital microscope at 40× magnification. Data were analyzed using analysis of variance (ANOVA) and Results: Before thermocycling, the ZirCAD Prime group demonstrated the lowest overall mean and standard deviation (SD) marginal discrepancy values (55.76 ± 16.41 µm), followed by Zolid Bion (60.95 ± 16.64 µm) and Cercon ht ML (62.93 ± 20.79 µm). After thermocycling, the ZirCAD Prime group demonstrated the lowest discrepancy in overall mean and standard deviation (57.18 ± 16.43 µm), followed by Zolid Bion (62.92 ± 16.31 µm) and Cercon ht ML (63.83 ± 20.92 µm). ANOVA revealed no significant difference in the zirconia groups before ( Conclusion: After thermocycling, all types of CAD/CAM zirconia crowns showed an increase in marginal discrepancies, but these differences remained within clinically acceptable limits. How to cite this article: Alshehri AH. The Impact of Thermocycling on the Marginal Discrepancy of Zirconia CAD/CAM Generation on Central Incisors: An

Indexed as

Central incisorsComputer-aided design/computer-aided manufacturingMarginal discrepanciesThermocyclingZirconia generations

Identifiers

PMID41113782
PMCPMC12532235

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.