ArticleComputational and structural biotechnology journal2025
Teleoperated robotic surgical system for percutaneous coronary intervention.
Article in Computational and structural biotechnology journal, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Heart disease has been the leading cause of death worldwide for decades. Today, Percutaneous Coronary Intervention (PCI) has become the gold standard for treating heart disease due to its minimally invasive nature, effectively reducing the time for both surgery and recovery. During a PCI procedure, the surgeon injects a contrast agent into the coronary arteries and uses live X-ray images to obtain information on blockages. However, prolonged radiation exposure could cause dose accumulation and harm to surgeons. Recently, major technological advancements in robotic surgery have made minimally invasive surgery easier. In contrast, only a few robotic surgical systems have been developed for PCI with semi-automation. In this study, the framework of a teleoperated PCI robotic surgical system, mimicking the common manipulation techniques by surgeons such as push, pull, and rotation, was developed. The framework consists of three major components: a surgeon side, a patient side, and an automatic delivery system. The automatic delivery system supplies the guidewire and catheter into the patient side. The surgeon remotely controls the patient-side robot from the surgeon side to perform a teleoperated PCI procedure, eliminating the need for medical personnel in the surgery room and addressing prolonged radiation exposure issues. To ensure the response accuracy between the surgeon side and patient side, PI controllers are incorporated into the control architecture. These PI controllers, designed using Particle Swarm Optimization, demonstrate high performance and meet the desired goals. The system performance of this PCI robotic surgical system has been validated in a silicone vascular model.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.