Evidence map›Paper›PMID 41112966›Full record

ArticleJournal of neuroendovascular therapy2025

Vascular Reconstruction Device for Coil Embolization of Wide-Neck Type Cerebral Aneurysm: Findings from a Post-Marketing Surveillance Study in Japan.

Yoichiro Kawamura, Atsuko Honda, Akio Hyodo, Shigeru Miyachi, Yuji Matsumaru, Waro Taki, Yasushi Ito, Naoya Kuwayama, Hirotoshi Imamura, Takashi Izumi and 2 more

Abstract read
In one paragraph

Article in Journal of neuroendovascular therapy, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Yoichiro KawamuraJohnson & Johnson K.K. Medical Company, Tokyo, Japan.
Atsuko HondaJohnson & Johnson K.K. Medical Company, Tokyo, Japan.
Akio HyodoDepartment of Neurosurgery, Kamagaya General Hospital, Kamagaya, Chiba, Japan.
Shigeru MiyachiDepartment of Neurological Surgery, Aichi Medical University, Nagakute, Aichi, Japan.
Yuji MatsumaruDepartment of Neurosurgery, Institute of Medicine, University of Tsukuba, Tsukuba, Ibaraki, Japan.
Waro TakiStroke Center/Department of Neurosurgery, Koseikai Takeda Hospital, Kyoto, Kyoto, Japan.
Yasushi ItoDepartment of Neurosurgery, Shinrakuen Hospital, Niigata, Niigata, Japan.
Naoya KuwayamaCerebral Vascular Center, Toyama Red Cross Hospital, Toyama, Toyama, Japan.
Hirotoshi ImamuraDepartment of Neurosurgery, National Cerebral and Cardiovascular Center Hospital, Suita, Osaka, Japan.
Takashi IzumiDepartment of Neurosurgery, Nagoya University Hospital, Nagoya, Aichi, Japan.
Chiaki SakaiRegulatory Science of Medical Device Development and Innovation, Kyoto University Graduate School of Medicine, Kyoto, Kyoto, Japan.
Nobuyuki SakaiDepartment of Neurovascular Research and Department of Neurosurgery, Kobe City Medical Center General Hospital, Kobe, Hyogo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: Endovascular treatment of wide-neck cerebral aneurysms with conventional coiling alone remains challenging. Stent-assisted coiling using a vascular reconstruction device offers an alternative strategy. This study evaluated the safety and effectiveness of the Enterprise Vascular Reconstruction Device (Cerenovus, Irvine, CA, USA) in patients with wide-neck cerebral aneurysms. Methods: Post-marketing surveillance records were collected for all Enterprise stent usage using case report forms at 30 days and at 1, 2, and 3 years post-procedure. A total of 738 cases, including 411 on-label cases, were analyzed across 83 hospitals. Results: Stent deployment was successful in 98.8% of cases, and the overall procedure success rate was 93.9% immediately post-procedure. The aneurysm occlusion rate was 92.90%, with 73.7% classified as Raymond-Roy class I/II immediately post-procedure. Among the 411 on-label cases, 17 patients (4.1%) demonstrated worsening of the modified Rankin Scale score, but no deaths were attributable to the utilization of the Enterprise device. The postoperative ischemic stroke complication rate was low (4.5%) but increased significantly in patients with a proximal parent artery diameter <2.5 mm (18.6%) and in those aged ≥65 years (8%). Multivariable logistic regression revealed that age ≥65 years, diabetes, hypertension, and a past medical history of ischemic stroke were significant risk factors for postoperative ischemic stroke. Conclusion: Vascular reconstruction device implantation was effective and safe for treating wide-neck cerebral aneurysms.

Indexed as

cerebral aneurysmEnterprisestent assisted coilingvascular reconstruction devicewide-neck aneurysm

Identifiers

PMID41112966
PMCPMC12530950

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.