Evidence map›Paper›PMID 41112166›Full record

ArticleJournal of arrhythmia2025

Cryoballoon Ablation of the Left Common Pulmonary Vein Using a Size-Adjustable Cryoballoon: A Comparative Study.

Hirofumi Arai, Yasuteru Yamauchi, Yuichiro Sagawa, Kazuya Murata, Atsuhito Oda, Yumi Yasui, Junichi Kishaba, Hideki Arima, Shinsuke Miyazaki, Tetsuo Sasano

Abstract read
In one paragraph

Article in Journal of arrhythmia, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Hirofumi AraiDepartment of Cardiology Japan Red Cross Yokohama City Bay Hospital Yokohama Kanagawa Japan.ORCID https://orcid.org/0000-0001-9343-4614
Yasuteru YamauchiDepartment of Cardiology Japan Red Cross Yokohama City Bay Hospital Yokohama Kanagawa Japan.ORCID https://orcid.org/0000-0002-4661-2999
Yuichiro SagawaDepartment of Cardiology Japan Red Cross Yokohama City Bay Hospital Yokohama Kanagawa Japan.ORCID https://orcid.org/0000-0002-2588-3757
Kazuya MurataDepartment of Cardiology Japan Red Cross Yokohama City Bay Hospital Yokohama Kanagawa Japan.
Atsuhito OdaDepartment of Cardiology Japan Red Cross Yokohama City Bay Hospital Yokohama Kanagawa Japan.
Yumi YasuiDepartment of Cardiology Japan Red Cross Yokohama City Bay Hospital Yokohama Kanagawa Japan.
Junichi KishabaDepartment of Cardiology Japan Red Cross Yokohama City Bay Hospital Yokohama Kanagawa Japan.
Hideki ArimaDepartment of Cardiology Japan Red Cross Yokohama City Bay Hospital Yokohama Kanagawa Japan.
Shinsuke MiyazakiDepartment of Cardiovascular Medicine Institute of Science Tokyo Bunkyo Tokyo Japan.ORCID https://orcid.org/0000-0002-0230-0934
Tetsuo SasanoDepartment of Cardiovascular Medicine Institute of Science Tokyo Bunkyo Tokyo Japan.ORCID https://orcid.org/0000-0003-3582-6104

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The efficacy of cryoballoon ablation (CBA) using a 28-mm or 31-mm cryoballoon for isolating the left common pulmonary vein (LCPV) remains poorly established. We aimed to evaluate procedural outcomes and long-term follow-up data of CBA for the LCPV using either POLARx with a fixed 28-mm cryoballoon or POLARx FIT with a size-adjustable 28-mm or 31-mm cryoballoon. Methods: Patients with LCPV who underwent CBA for atrial fibrillation using POLARx or POLARx FIT between January 2022 and April 2024 were retrospectively analyzed. Procedural outcomes and long-term follow-up data were compared between the POLARx and POLARx FIT groups. Results: Fifty-one patients (32 males [62.7%]; mean age, 66 ± 11.6 years) were analyzed. The POLARx group included 23 patients, and the POLARx FIT group included 28 patients. First-freeze pulmonary vein isolation (PVI) success was 1 (4.3%) versus 8 (28.6%) ( Conclusions: POLARx FIT was useful for LCPV isolation, with a higher first-freeze PVI success rate, fewer applications, and shorter total freezing time compared to POLARx.

Indexed as

atrial fibrillationcatheter ablationcryoablationpulmonary veinstreatment outcome

Identifiers

PMID41112166
PMCPMC12534196

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.