Evidence map›Paper›PMID 41109867›Full record

Observational studyEuropean radiology2026

Computed tomography pulmonary angiography in around-the-clock clinical care with individualised scan protocols: a 5-year observational study on incidence and causes of repeat scanning.

Estelle C Nijssen, Bibi Martens, Babs M Hendriks, Hester A Gietema, Joachim E Wildberger, Cécile R L P N Jeukens

Abstract readObservational Study
In one paragraph

Observational study in European radiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Estelle C NijssenDepartment of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht, The Netherlands. estelle.nijssen@mumc.nl.ORCID http://orcid.org/0000-0001-5537-3283
Bibi MartensDepartment of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht, The Netherlands.
Babs M HendriksDepartment of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht, The Netherlands.
Hester A GietemaDepartment of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht, The Netherlands.
Joachim E WildbergerDepartment of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht, The Netherlands.
Cécile R L P N JeukensDepartment of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesElevated repeat-scanning rates are reported for CT pulmonary angiography (CTPA). Individualised protocols optimise contrast- and radiation-doses, but whether this affects repeat scanning is unknown. The current study evaluates repeat-CTPA in a 24/7, state-of-the-art clinical-care setting. MATERIALS AND

methodsThis is a retrospective observational single-centre study of consecutive CTPA acquired over a 5-year period during standard clinical care. The primary outcome is the repeat-scan rate. Repeat- and single-scan groups were compared for initial-scan characteristics (patient-related, CT-scanner, contrast-administration, kV-settings, regular hours/shifts, radiation-dose), and cumulative contrast- and radiation-doses. An expert radiologist panel retrospectively evaluated probable reasons for repeat scanning through visual, subjective assessment of initial-scan images.

resultsCTPA repeat rate was 3.1% (139/4467). Repeat- and single-scan groups significantly differed: age (55 ± 18 vs. 63 ± 17 years; p < 0.001), Body Mass Index (27 kg/m

conclusionIndividualised scan protocols yielded diagnostic images around the clock, with repeat scanning well within ranges published in the literature. Retrospective expert evaluation suggests repeat rates as low as 1.2% may be possible. Repeat- and single-scan groups significantly differed in patient characteristics, and repeat-scanning reasons were mostly patient-related. These results suggest further tailoring protocols to (younger, female) patients might be beneficial in helping to further reduce CTPA-repeats. KEY POINTS: Question CT pulmonary angiography (CTPA) is subject to relatively high repeat-scanning rates, but it is not known how state-of-the-art CTPA and individualised protocols perform in clinical practice today. Findings During 5 years of clinical practice the repeat rate was 3%; retrospective expert image-evaluation suggests a repeat rate as low as 1.2% may be possible. Clinical relevance Repeat- and single-scan groups significantly differed in patient characteristics, and reasons for repeat scanning were mostly patient-related. Further tailoring protocols to (younger, female) patients may be the best focus to help reduce CTPA-repeats, improve safety, and reduce logistic burden.

Indexed as

Computed Tomography AngiographyPulmonary ArteryPulmonary EmbolismAdultAgedContrast MediaFemaleHumansIncidenceMaleMiddle AgedRadiation DosageRetrospective StudiesContrast MediaComputed tomography angiographyDiagnostic imagingMultidetector computed tomographyPrecision medicinePulmonary embolism

Identifiers

PMID41109867
PMCPMC13035654

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.