Evidence map›Paper›PMID 41104126›Full record

ArticleImaging neuroscience (Cambridge, Mass.)2025

The RF Cap: A 26-channel flexible RF coil cap for optimized concurrent TMS/fMRI experiments at 3T.

Lucia I Navarro de Lara, Sebastian Ardila, Lincoln Craven-Brightman, Evgenii Kim, Mohammad Daneshzand, Lawrence L Wald, Jyrki Ahveninen, Jason P Stockmann, Aapo Nummenmaa

Abstract read
In one paragraph

Article in Imaging neuroscience (Cambridge, Mass.), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Lucia I Navarro de LaraAthinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, United States.ORCID https://orcid.org/0000-0002-6793-4831
Sebastian ArdilaAthinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, United States.
Lincoln Craven-BrightmanAthinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, United States.
Evgenii KimAthinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, United States.
Mohammad DaneshzandAthinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, United States.
Lawrence L WaldAthinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, United States.
Jyrki AhveninenAthinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, United States.
Jason P StockmannAthinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, United States.
Aapo NummenmaaAthinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, United States.

Funding

Training and Dissemination CoreP41EB030006 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI Susie Yi Huang, BRUCE R ROSEN · 2020 to 2026
$10.9M
Collaborative robot (cobot) controlled system for transcranial magnetic stimulationS10OD028668 · OD · MASSACHUSETTS GENERAL HOSPITAL · PI NUMMENMAA, AAPO · 2021 to 2021
$558k
Probing network-specific cortical connectivity by combining multifocal transcranial magnetic stimulation with electroencephalographyK01MH138823 · NIMH · MASSACHUSETTS GENERAL HOSPITAL · PI Mohammad Daneshzand · 2024 to 2026
$549k
Wearable RF-EEG Cap for closed loop TMS/fMRI/EEG ApplicationsR00EB032749 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI Lucia Isabel Navarro de Lara · 2025 to 2026
$473k
Wearable RF-EEG Cap for closed loopTMS/fMRI/EEG ApplicationsK99EB032749 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI NAVARRO DE LARA, LUCIA ISABEL · 2022 to 2023
$381k
NIBIB NIH HHS K99 EB032749NIBIB NIH HHS P41 EB030006NIBIB NIH HHS R00 EB032749NIH HHS S10 OD028668NIMH NIH HHS K01 MH138823
6 · The paper itself

Abstract

Combining brain imaging methods with non-invasive brain stimulation such as transcranial magnetic stimulation (TMS) is a rapidly expanding field with the potential to drastically improve the understanding of brain function. However, currently there is no generally applicable hardware solution optimized for these types of acquisitions. To make concurrent TMS/fMRI experiments at 3 T feasible without sacrificing imaging quality, we have designed, constructed, and tested the first of its kind "RF Cap": a 26-channel flexible RF coil cap. The RF Cap achieves full brain coverage with high sensitivity while allowing the administration of TMS at most targets over the scalp with an easy setup and possibility of using a neuronavigation system. The RF Cap consists of a FLEXIBLE and a RIGID part. The FLEXIBLE part is a neoprene cap with 26 flexible RF coaxial cable loops sewn onto it and distributed following a soccer ball layout. The RF elements were interfaced using flexible PCBs and incorporating a BALUN to minimize common modes on the short cables connecting the elements to their preamplifiers placed on the RIGID part. This solution provides a user-friendly approach for concurrent TMS/fMRI acquisitions while ensuring optimal patient comfort. We show that the RF Cap offers at least 4 times more SNR than a birdcage coil at the center of the brain and 10-16 times more SNR on the cortex. The effects of the TMS on the SNR of the RF Cap are between 10% and 25% loss over the region where the TMS coil is placed. The RF Cap has the potential to transform concurrent TMS/fMRI into a practical and useful neuroscientific tool as well as to pave the way for future clinical applications.

Indexed as

concurrent TMS/fMRIflexible RF coilsMRI of neuromodulation

Identifiers

PMID41104126
PMCPMC12521982

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.