Evidence map›Paper›PMID 41104100›Full record

ArticleFrontiers in bioengineering and biotechnology2025

Biomechanical comparison of the anterior reverse PHILOS and locking compression plate extra-articular distal humerus plates for extra-articular distal humeral fractures.

Apipop Kritsaneephaiboon, Sujin Wanchat, Thammaphong Khongkanin, Atichart Kwanyuang, Satta Srewaradachpisal, Kantapon Dissaneewate, Wich Orapiriyakul

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Apipop KritsaneephaiboonDepartment of Orthopedics, Faculty of Medicine, Prince of Songkla University, Songkhla, Thailand.
Sujin WanchatDepartment of Mechanical Engineering, Faculty of Engineering at Sriracha, Kasetsart University, Sriracha, Chonburi, Thailand.
Thammaphong KhongkaninFaculty of Medicine Siriraj Hospital, Golden Jubilee Medical Center, Mahidol University, Nakhon Pathom, Thailand.
Atichart KwanyuangInstitute of Biomechanical Engineering, Faculty of Medicine, Prince of Songkla University, Songkhla, Thailand.
Satta SrewaradachpisalDepartment of Mechanical Engineering, Faculty of Engineering, Prince of Songkla University, Songkhla, Thailand.
Kantapon DissaneewateDepartment of Orthopedics, Faculty of Medicine, Prince of Songkla University, Songkhla, Thailand.
Wich OrapiriyakulDepartment of Orthopedics, Faculty of Medicine, Prince of Songkla University, Songkhla, Thailand.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The locking compression plate extra-articular distal humeral plate (EADHP) is an anatomically pre-contoured plate that is used for extra-articular distal humeral fractures. However, there is currently no standard criterion for the internal fixation of this type of fracture. Moreover, the anterior reverse proximal humeral internal locking system (PHILOS) plate (ARPP) has been clinically applied as a new internal-fixation plate without testing in biomechanical studies. We aimed to compare the biomechanical properties of ARPP and EADHP for the definitive fixation of extra-articular distal humeral fractures. Methods: Eighteen composite humerus bones were cut at the distal humerus using an electrical saw to generate a fracture gap. Internal fixation via the ARPP or EADHP was performed following standard techniques. An Instron testing machine (Instron 8872) was used to evaluate biomechanical properties by applying bending torque, axial force, and torsional torque. Results: Fixations with both ARPP and EADHP could withstand forces that exceeded the physiological forces (200 N). Under axial compression, ARPP constructs demonstrated greater stiffness (668.9 ± 120.7 N/mm vs 171.2 ± 45.4 N/mm) and higher maximal load-to-failure (2,092.6 ± 305.2 N vs 907.0 ± 56.5 N) compared with EADHP, although these differences were not statistically significant. During anterior bending, ARPP provided significantly higher stiffness (17.8 ± 2.0 N/mm vs 13.9 ± 1.0 N/mm, Conclusion: ARPP demonstrated superior bending stiffness compared with the EADHP, while both constructs performed equivalently in axial compression and torsion. Therefore, ARPP can serve as an alternative internal-fixation method for extra-articular distal humeral fractures.

Indexed as

biomechanical studydistal humeral fractureextra-articularinternal-fixation methodPHILOS

Identifiers

PMID41104100
PMCPMC12521443

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.