Evidence map›Paper›PMID 41103564›Full record

ArticleJournal of biomedical optics2025

Digital holographic microscopy for rapid bacteria segmentation and counting in microfluidic cartridges: basic considerations and limitations for diagnostic application.

Hussein Kamel, Julian Schmid, Moaaz Rauf Nizami, Igor Alekseenko, Florian Hausladen, Daniel Claus, Rainer Wittig, Damien P Kelly

Abstract read
In one paragraph

Article in Journal of biomedical optics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Hussein KamelInstitut für Lasertechnologien in der Medizin und Messtechnik an der Universität Ulm (ILM), Ulm, Germany.
Julian SchmidInstitut für Lasertechnologien in der Medizin und Messtechnik an der Universität Ulm (ILM), Ulm, Germany.
Moaaz Rauf NizamiInstitut für Lasertechnologien in der Medizin und Messtechnik an der Universität Ulm (ILM), Ulm, Germany.
Igor AlekseenkoInstitut für Lasertechnologien in der Medizin und Messtechnik an der Universität Ulm (ILM), Ulm, Germany.
Florian HausladenInstitut für Lasertechnologien in der Medizin und Messtechnik an der Universität Ulm (ILM), Ulm, Germany.
Daniel ClausInstitut für Lasertechnologien in der Medizin und Messtechnik an der Universität Ulm (ILM), Ulm, Germany.
Rainer WittigInstitut für Lasertechnologien in der Medizin und Messtechnik an der Universität Ulm (ILM), Ulm, Germany.ORCID https://orcid.org/0000-0002-3735-9370
Damien P KellyInstitut für Lasertechnologien in der Medizin und Messtechnik an der Universität Ulm (ILM), Ulm, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Significance: Digital holographic microscopy (DHM) has proven effective for particle segmentation within a given volume, making it well-suited for rapid monitoring of bacterial growth in microfluidic cartridges-such as in single-cell-based antimicrobial susceptibility testing assays. However, the development of optimal assays depends on a range of factors related to the instrument, consumables, and the sample itself. Despite this, comprehensive investigations into how these parameters influence the quality of the resulting phase images remain limited. Aim: To address this problem, we systematically explore the effect of these factors, including the microfluidic chamber height and its material properties, the density of the suspension, and other sample-inherent properties, on the signal-to-noise ratio (SNR) of the reconstructed phase image. Approach: We constructed an off-axis digital holographic microscope and defined a robust numerical processing pipeline allowing for the numerical reconstruction, refocusing and counting of suspended particles in a measurement volume spanning roughly Results: Experimental results demonstrated the system's capability in reflecting the dilution steps over 2 to 3 orders of magnitude. Our SNR analysis highlighted the microfluidic chamber height and the density of the suspension as key contributors to the background noise, whereas the particles themselves seemed to have a negligible effect. From this insight, we were able to derive an analytical function to predict the SNR of a given DHM system for various concentrations, chamber heights, and particle types. Conclusions: We successfully built a DHM system for counting suspended particles over a wide concentration range and for various microfluidic chamber heights. We also derived an initial framework for predicting and optimizing the performance of a given DHM system.

Indexed as

BacteriaHolographyMicrofluidic Analytical TechniquesMicroscopyEquipment DesignEscherichia coliImage Processing, Computer-AssistedLab-On-A-Chip DevicesMicrofluidicsQuantitative Phase ImagingSignal-To-Noise Ratiobacteriadigital holographic microscopymicrofluidicnumerical refocusingoff-axis holographysignal-to-noise ratio