Evidence map›Paper›PMID 41102661›Full record

ArticleBMC musculoskeletal disorders2025

Is zero-profile fixation safe in consecutive two-level anterior cervical discectomy and fusion with partial uncinate resection? A finite element analysis.

Ning Wu, Jiarui Zhang, Zhilin Ge, Rueishiuan Jiang, Lingxi Cai, Siqi Zhang, Jiying Wei, Kai Tang

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Ning Wu *Spinal Surgery, Ganzhou Hospital of Traditional Chinese Medicine, Ganzhou, Jiangxi Province, 341004, China.
Jiarui Zhang *School of Public Health and Management, Guangzhou University of Chinese Medicine, Guangzhou, 511495, China.
Zhilin GeGuangzhou University of Chinese Medicine, Guangzhou, 510000, China.
Rueishiuan JiangGuangzhou University of Chinese Medicine, Guangzhou, 510000, China.
Lingxi CaiThe Second Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510006, China.
Siqi ZhangGuangzhou University of Chinese Medicine, Guangzhou, 510000, China.
Jiying WeiSecond Clinical School, Guangzhou Medical University, Guangzhou, 511436, China.
Kai TangGuangzhou University of Chinese Medicine, Guangzhou, 510000, China. 20191109205@stu.gzucm.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe necessity and extent of uncinate process resection (UPR) during anterior cervical discectomy and fusion remains controversial. The Zero-Profile device offers a low-profile alternative to traditional plate-cage systems but its biomechanical stability following various degrees of UPR, particularly in two-level ACDF, has not been clearly established.

methodsThis computational finite element analysis used a validated three-dimensional C2–T1 cervical spine model to simulate Two-Level ACDF (C4–C6) with a Zero-Profile construct under three unilateral uncinate process resection (UPR) conditions (0%, 30%, 50%). No clinical or cadaveric experiments were performed. Under six physiological motions (flexion, extension, left/right lateral bending, left/right axial rotation), we quantified global and segmental range of motion (ROM), adjacent-segment ROM, von Mises stress in the implant, vertebral body and endplate stresses, intradiscal pressure (IDP), and maximum displacement.

resultsUnilateral UPR led to a dose-dependent deterioration in biomechanical stability. In the 50% UPR model, the ROM of the C4/5 segment increased by 29.4% in flexion and 16.7% in lateral bending, while adjacent levels (C3/4 and C6/7) also exhibited elevated ROMs, indicating reduced segmental rigidity and increased compensatory motion. Stress on the fixation components rose significantly, with peak screw stress increasing by 47.1% and cage stress by 90.0% under flexion. Endplate stresses also increased, particularly in bending and rotation, with the C5 superior and C6 inferior endplates showing stress increments of 41.5% and 20.3%, respectively. Moreover, IDP at adjacent segments increased with greater UPR extent, reflecting enhanced load transmission to non-fused levels. The maximum construct displacement rose by 50.0% in flexion and 48.8% in axial rotation in the 50% UPR model, underscoring the progressive compromise of structural integrity. In contrast, the 30% UPR model demonstrated only mild changes in motion, stress, and displacement, suggesting that biomechanical performance remained within acceptable limits.

conclusionsExtensive UPR (≥ 50%) substantially compromises biomechanical stability in two-level ACDF using the ZP fixation, increasing mechanical load on implants and adjacent segments. ZP fixation appears acceptable when UPR is limited to 30%, but caution is warranted when higher resection is required. Surgeons should consider supplemental fixation strategies or alternative systems when extensive UPR is anticipated.

Indexed as

Cervical VertebraeDiskectomyFinite Element AnalysisSpinal FusionBiomechanical PhenomenaHumansRange of Motion, ArticularACDFCervical spineFinite element analysisUncovertebral jointZero-P

Identifiers

PMID41102661
PMCPMC12532917

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.