Evidence map›Paper›PMID 41095352›Full record

ArticleMaterials (Basel, Switzerland)2025

Loss Separation Modeling and Optimization of Permalloy Sheets for Low-Noise Magnetic Shielding Devices.

Yuzheng Ma, Minxia Shi, Yachao Zhang, Teng Li, Yusen Li, Leran Zhang, Shuai Yuan

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yuzheng MaKey Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation Science and Optoelectronics Engineering, Beihang University, Beijing 100191, China.ORCID 0009-0004-3734-2167
Minxia ShiKey Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation Science and Optoelectronics Engineering, Beihang University, Beijing 100191, China.
Yachao ZhangBeijing Institute of Aerospace Microsystem and Information Technology, Beijing 100094, China.
Teng LiKey Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation Science and Optoelectronics Engineering, Beihang University, Beijing 100191, China.
Yusen LiKey Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation Science and Optoelectronics Engineering, Beihang University, Beijing 100191, China.
Leran ZhangKey Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation Science and Optoelectronics Engineering, Beihang University, Beijing 100191, China.ORCID 0000-0002-4000-2276
Shuai YuanKey Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation Science and Optoelectronics Engineering, Beihang University, Beijing 100191, China.ORCID 0000-0002-2913-899X

Funding

National Double First-class Special Foundation of China Grant No. ZG216S2382National Postdoctoral Program for Innovative Talents BX20240463
6 · The paper itself

Abstract

With the breakthroughs in quantum theory and the rapid advancement of quantum precision measurement sensor technologies, atomic magnetometers based on the spin-exchange relaxation-free (SERF) mechanism have played an increasingly important role in ultra-weak biomagnetic field detection, inertial navigation, and fundamental physics research. To achieve high-precision measurements, SERF magnetometers must operate in an extremely weak magnetic field environment, while the detection of ultra-weak magnetic signals relies on a low-noise background. Therefore, accurate measurement, modeling, and analysis of magnetic noise in shielding materials are of critical importance. In this study, the magnetic noise of permalloy sheets was modeled, separated, and analyzed based on their measured magnetic properties, providing essential theoretical and experimental support for magnetic noise evaluation in shielding devices. First, a single-sheet tester (SST) was modeled via finite element analysis to investigate magnetization uniformity, and its structure was optimized by adding a supporting connection plate. Second, an experimental platform was established to verify magnetization uniformity and to perform accurate low-frequency measurements of hysteresis loops under different frequencies and field amplitudes while ensuring measurement precision. Finally, the Bertotti loss separation method combined with a PSO optimization algorithm was employed to accurately fit and analyze the three types of losses, thereby enabling precise separation and calculation of hysteresis loss. This provides essential theoretical foundations and primary data for magnetic noise evaluation in shielding devices.

Indexed as

Bertotti loss separation methodhysteresis noiseimaginary magnetic permeabilitymagnetic propertiesSST measuring device

Identifiers

PMID41095352
PMCPMC12526318

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked