Evidence map›Paper›PMID 41095081›Full record

ArticleSensors (Basel, Switzerland)2025

Design and Implementation of an Inductive Proximity Sensor with Embedded Systems.

Septimiu Sever Pop, Alexandru-Florin Flutur, Alexandra Fodor

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Septimiu Sever PopApplied Electronics Department, Faculty of Electronics, Telecommunications and Information Technology, Technical University of Cluj-Napoca, 400027 Cluj-Napoca, Romania.
Alexandru-Florin FluturApplied Electronics Department, Faculty of Electronics, Telecommunications and Information Technology, Technical University of Cluj-Napoca, 400027 Cluj-Napoca, Romania.
Alexandra FodorApplied Electronics Department, Faculty of Electronics, Telecommunications and Information Technology, Technical University of Cluj-Napoca, 400027 Cluj-Napoca, Romania.ORCID 0000-0003-1290-4560

Funding

Hidroelectrica S.A., through the UCCH Department, a Romanian national company project no. N-C-ST 15728/15.05.2024National Program for Research of the National Association of Technical Universities - GNAC ARUT 2023 contract 15/1.07.2024, ID 1962
6 · The paper itself

Abstract

Non-mechanical contact distance measurement solutions are becoming more and more necessary in various industries, including building monitoring, automotive, and aviation industries. Inductive proximity sensor (IPS) technology is becoming a more popular solution in the field of short distances. Because of its small size, dependability, and measurement capabilities, IPS is a good option. Separate circuits are used in the classical structures to generate the excitation signal for the sensor coil and measure the response signal. The response signal's amplitude is typically measured. This article proposes an IPS model that uses frequency response as its basis for operation. A microcontroller and embedded technology are used to implement a small IPS structure. This includes the circuit for determining distance, as well as the signal generator used to excite the sensor coil. In essence, an LC circuit is employed, which at the unit step has a damped oscillatory response by nature. Periodically injecting energy into the LC circuit, however, causes it to enter a persistent oscillatory state. The full experimental model is implemented and presented in the article, illustrating how the distance can be measured with a 33 µm accuracy within the 10 mm range with the help of the nonlinear relationship between frequency and distance and the linear drift of frequency with temperature.

Indexed as

displacement measurementembeddedfrequencyinductive proximity sensorLC oscillator

Identifiers

PMID41095081
PMCPMC12526581

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.