Evidence map›Paper›PMID 41094548›Full record

ArticleInternational journal of retina and vitreous2025

Semantic segmentation of the avascular zone of the fovea in optical coherence tomography angiography: evaluation of techniques and applications in ocular diseases.

Brena Fernanda de Sousa Carvalho, Alexandre Antônio Marques Rosa, Rafael Scherer, Valberto Monteiro Nunes, Francisco Vinícius Moraes de Souza, José Leandro Nascimento da Silva, Taurino Dos Santos Rodrigues Neto

Abstract read
In one paragraph

Article in International journal of retina and vitreous, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Brena Fernanda de Sousa CarvalhoFederal University of Pará (UFPA), Castanhal, Brazil.
Alexandre Antônio Marques RosaFederal University of Pará (UFPA), Castanhal, Brazil.
Rafael SchererArtificial Intelligence and Computer Vision Applied to Medical Imaging, University of São Paulo (USP), São Paulo, Brazil.
Valberto Monteiro NunesFederal University of Pará (UFPA), Castanhal, Brazil.
Francisco Vinícius Moraes de SouzaFederal University of Pará (UFPA), Castanhal, Brazil.
José Leandro Nascimento da SilvaFederal University of Pará (UFPA), Castanhal, Brazil.
Taurino Dos Santos Rodrigues NetoUniversity of São Paulo Medical School, Av. Dr. Enéas de Carvalho Aguiar, 255, Cerqueira César, São Paulo, SP, 05403-001, Brazil. taurinorodrigues@gmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThis study addresses the use of zero-shot learning (ZSL) for segmentation of the foveal avascular zone (FAZ) in optical coherence tomography (OCT) images obtained through the RedCheck® platform. Accurate FAZ segmentation is essential for ophthalmologic diagnoses in conditions such as diabetic retinopathy and age-related macular degeneration. The proposed method aims to overcome the limitation of labeled data, reducing both the cost and time associated with model training.

methodsA total of 200 images from healthy patients were used. A neural network-based model was employed to identify the FAZ without specific labeled data, using pre-trained representations for contextual learning. Model performance was evaluated by comparing the automatic segmentation results with the manual annotations provided by specialists.

resultsQuantitative analysis revealed a mean intersection over union (MIoU) of 0.86, indicating consistent model performance in identifying regions of interest. The median IoU was 0.89, with an interquartile range between 0.85 (Q1) and 0.92 (Q3), demonstrating the method’s precision in most samples. Extreme values showed a maximum IOU of 0.97, reflecting excellent agreement, whereas the minimum IoU of 0.03 revealed limitations in atypical cases. The standard deviation of 0.11 indicated moderate variation in the results, and the 95% confidence interval for the MIoU ranged from 0.84 to 0.89, ensuring the statistical reliability of the approach. DISCUSSION: The findings demonstrate the feasibility and accuracy of the ZSL-based method for FAZ segmentation, even in the absence of labeled data. Despite the positive results, variability observed in specific images highlights the need for improvements to increase the model’s robustness in more heterogeneous data scenarios.

Indexed as

Foveal avascular zone (FAZ)Optical coherence tomography (OCT)Semantic segmentationZero-shot learning (ZSL)

Identifiers

PMID41094548
PMCPMC12522359

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.