Evidence map›Paper›PMID 41089896›Full record

ArticleJournal of spine surgery (Hong Kong)2025

Utilization of a mechanical hinge-powered operative table in thoracic spinal cord decompression and fusion: a report of two cases.

Dustin H Massel, Michael Patetta, John Paul Kolcun, Neil Mohile, Karan Patel, Cameron Kia, Christopher J DeWald

Abstract readCase Reports
In one paragraph

Article in Journal of spine surgery (Hong Kong), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Dustin H MasselDepartment of Orthopaedic Surgery, Endeavor Health, Skokie, IL, USA.ORCID https://orcid.org/0000-0002-8147-5555
Michael PatettaDepartment of Orthopaedics, University of Illinois Chicago College of Medicine, Chicago, IL, USA.
John Paul KolcunDepartment of Neurosurgery, Rush University Medical Center, Chicago, IL, USA.
Neil MohileDepartment of Orthopaedics, Rush University Medical Center, Chicago, IL, USA.
Karan PatelDepartment of Orthopaedics, Rush University Medical Center, Chicago, IL, USA.
Cameron KiaDepartment of Orthopaedics, Rush University Medical Center, Chicago, IL, USA.
Christopher J DeWaldDepartment of Orthopaedics, Rush University Medical Center, Chicago, IL, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The current case study identifies an alternative use of the ProAxis® Table by Mizuho | OSI (ProAxis) during thoracic cord decompression prior to final stabilization. We present two cases of thoracic cord compression with progressive neurologic decline associated with patient positioning during advanced imaging acquisition and intraoperatively, with a solution to intraoperative neurologic deterioration. Case Description: Case 1: a 59-year-old female with history of T11-pelvis posterior instrumented fusion for deformity presented with adjacent segment disease, excessive segmental kyphosis, and herniated disc at T10-T11. The patient reported severe midback pain and progressive neurologic deterioration with weakness in bilateral lower extremities (BLE). The patient was indicated for thoracic decompression and fusion extension. Preoperative somatosensory evoked potentials (SSEPs) and motor evoked potentials (MEPs) were intact. Upon prone positioning on an open Jackson frame, SSEPs were lost in BLE. A Stagnara Wake Up test with the patient positioned in flexion on the hospital stretcher confirmed acute neurologic injury with rapid functional recovery. The patient was ultimately treated with thoracic laminectomy, T9-T11, and extension of fusion to T4 on a ProAxis with decompression performed in 28-degrees flexion and subsequent table flattening to neutral over the course of the procedure. No neuromonitoring abnormalities were identified. The patient awoke with full motor strength. Case 2: a 68-year-old male with history of metastatic prostate cancer presented with high grade epidural spinal cord compression resulting from metastatic tumor to T6-T7 with acute American Spinal Injury Association (ASIA) B neurologic grade after a fall from standing height. The patient was indicated for emergent thoracic decompression and fusion. Upon advanced imaging acquisition, the patients' neurologic function further deteriorated. Intraoperatively the patient was positioned prone in flexion on a ProAxis at baseline 20-degrees thoracic kyphosis. No neuromonitoring changes were appreciated throughout the procedure. The patient's motor strength improved throughout his hospitalization with near full motor strength recovery in his BLE at final follow-up. Conclusions: We present two cases in which the ProAxis was used to maintain patient alignment during thoracic decompression at a degree associated with preoperative neurologic function with resultant restoration of neurologic function in the postoperative period.

Indexed as

case reportProAxis tablethoracic decompressionthoracic spinal cord compression

Identifiers

PMID41089896
PMCPMC12516576

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked