ArticleGeneral thoracic and cardiovascular surgery cases2025
Unanticipated stenosis of the distal edge of frozen elephant trunk caused by retrograde perfusion: A case report.
Article in General thoracic and cardiovascular surgery cases, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Potential deformation of the stented portion in partial frozen elephant trunk: a double-edged sword during retrograde flow under retrograde perfusion.General thoracic and cardiovascular surgery cases · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTotal arch replacement with frozen elephant trunk (FET) has been reported to be associated with favorable aortic remodeling when used for aortic dissection. However, several complications associated with FET have been reported, including distal stent graft-induced new entry (dSINE), which potentially results in aortic rupture and late mortality. Frozenix Partial ET (Japan Lifeline Inc., Tokyo, Japan) is a unique FET device that has a non-stent zone at the distal 2 cm end to decrease the radial force to lower the incidence of dSINE. Owing to its novelty, there are few preceding literatures regarding its efficacy and complications. In this report, we present a case of an unanticipated complication arising from the use of Frozenix Partial ET subsequent to the initiation of extracorporeal membrane oxygenation (ECMO). CASE PRESENTATION: A 54-year-old male diagnosed with Stanford type A acute aortic dissection underwent emergency total aortic arch replacement, frozen elephant trunk with Frozenix partial ET (Japan Lifeline Inc., Tokyo, Japan), the Bentall procedure, and coronary artery bypass grafting. The patient developed cardiogenic shock, requiring extracorporeal membrane oxygenation with left common femoral artery and vein cannulation on postoperative day 1. Despite adequate ECMO flow, high doses of catecholamines were required to maintain blood pressure measured at the right radial artery. Transesophageal echocardiography revealed stenosis of the distal part of the FET presumably due to retrograde perfusion from the femoral artery. The addition of left axillary artery cannulation improved systemic circulation, reducing the dose of catecholamine.
conclusionAlthough designed to reduce the risk of dSINE, Frozenix Partial ET may induce unforeseen complications. Particularly, its non-stent distal part can become stenotic under conditions of retrograde perfusion. Surgeons should carefully choose where to cannulate in patients with this device requiring redo surgery or ECMO support.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.