Evidence map›Paper›PMID 41087746›Full record

ArticleAnalytical and bioanalytical chemistry2025

Gas chromatography-triple quadrupole mass spectrometry method for analysis of polychlorinated dibenzo-p-dioxins, dibenzofurans: evaluation and application to sediment samples.

Xuyen Thi Nguyen, Hang Thi Hong Mai, Anh Duc Dam, Dat Tien Nguyen, Minh Binh Tu, Binh Dinh Chu, Nam Duc Vu

Abstract read
PubMed Publisher
In one paragraph

Article in Analytical and bioanalytical chemistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Xuyen Thi NguyenCenter for High Technology Research and Development, Vietnam Academy of Science and Technology, Hanoi, Vietnam.ORCID http://orcid.org/0009-0007-4861-596X
Hang Thi Hong MaiCenter for High Technology Research and Development, Vietnam Academy of Science and Technology, Hanoi, Vietnam.
Anh Duc DamCenter for High Technology Research and Development, Vietnam Academy of Science and Technology, Hanoi, Vietnam.
Dat Tien NguyenCenter for High Technology Research and Development, Vietnam Academy of Science and Technology, Hanoi, Vietnam.
Minh Binh TuFaculty of Chemistry, University of Science, Vietnam National University, Hanoi, Hanoi, Vietnam.
Binh Dinh ChuSchool of Chemistry and Life Sciences, Hanoi University of Science and Technology, Hanoi, Vietnam.ORCID http://orcid.org/0000-0003-2784-1515
Nam Duc VuCenter for High Technology Research and Development, Vietnam Academy of Science and Technology, Hanoi, Vietnam. vuducnam@gmail.com.ORCID http://orcid.org/0000-0003-1455-8024

Funding

Vingroup Innovation Foundation VINIF.2024.TS.028
6 · The paper itself

Abstract

A study was conducted to validate the gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS) method as a cost-effective method for the analysis of polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDD/Fs) in sediment samples. The instrument sensitivity for 17 PCDD/Fs congeners was determined to be in the range of 0.201 to 1.45 ng/mL. The four-point calibration curve exhibited high linearity, with the mean relative response factors (RRFs) for PCDD/Fs ranging from 0.81 to 1.88, and RSD < 20% met the analytical requirements of the standard method for gas chromatography combined with high-resolution mass spectrometry (GC-HRMS). The quantification limit of PCDD/Fs in sediments analyzed by the GC-QqQ-MS method was demonstrated to be 2 to 21 times higher than that of the GC-HRMS method. The results of PCDD/Fs concentration analysis in sediment matrix for 1 certified reference material sample, 3 international proficiency test samples, and 29 marine sediment samples between the two analytical methods showed a relatively good agreement, with a relative difference of ± 25%. Furthermore, the gas chromatography method using triple quadrupole mass spectrometry can be regarded as a viable alternative to high-resolution mass spectrometry for sediment samples with total mass concentrations of PCDD/Fs in the 500-1000 pg/g range, and especially areas at risk of PCDD/Fs contamination.

Indexed as

GC-QqQ-MSPCDD/FsSedimentTriple quadrupole

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.