ArticleNature communications2025
Sub-ångström resolution ptychography in a scanning electron microscope at 20 keV.
Article in Nature communications, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Sub-ångström resolution ptychography in a scanning electron microscope at 20 keV.Nature communications · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Achieving sub-ångström (<1 Å) resolution in electron microscopy typically requires a high-energy (>30 keV) beam and a transmission electron microscope (TEM) fitted with an aberration corrector and a high efficiency, high pixel-count camera. The cost, space- and personnel-requirements of such TEMs is prohibitive for many laboratories. Low-energy (≤30 keV) scanning electron microscopes (SEMs), in comparison, offer a simpler, more compact, and cost-effective electron microscopy platform. Lower beam energies also have the potential to provide greater information from thin, light-element samples. Here, we demonstrate a sub-ångström resolution of 0.67 Å using a 20 keV SEM operated in transmission mode, enabled by ptychographic reconstruction. This resolution corresponds to a resolution-to-wavelength ratio of 7.8, surpassing previous results from electron ptychography and conventional imaging approaches. The gain in resolution is achieved through a multi-slice ptychographic algorithm incorporating diffraction distortion correction, coupled with a SEM fitted with a cold field emission source, immersion lens, simple projector lens, and a hybrid direct detector optimized for low-energy electrons. This approach holds immediate promise for high-resolution imaging of 2D materials and, with further development, may enable structural studies of small (<100 kDa) proteins.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.