Evidence map›Paper›PMID 41084102›Full record

Trial reportProsthetics and orthotics international2026

Reliability of a novel in vivo optical strain assessment of carbon fiber custom dynamic orthoses.

Sara M Magdziarz, Ana V Figueroa, Jessica E Goetz, Jason M Wilken

Abstract readRandomized Controlled Trial
In one paragraph

Trial report in Prosthetics and orthotics international, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Sara M MagdziarzDepartment of Physical Therapy and Rehabilitation Science, The University of Iowa Carver College of Medicine, Iowa City, IA, USA.ORCID 0009-0009-4335-4654
Ana V FigueroaDepartment of Orthopedics and Rehabilitation, The University of Iowa Carver College of Medicine, Iowa City, IA, USA.
Jessica E GoetzDepartment of Orthopedics and Rehabilitation, The University of Iowa Carver College of Medicine, Iowa City, IA, USA.ORCID 0000-0002-7197-5978
Jason M WilkenDepartment of Physical Therapy and Rehabilitation Science, The University of Iowa Carver College of Medicine, Iowa City, IA, USA.ORCID 0000-0002-5556-7667

Funding

University of Iowa Institute for Clinical and Translational ScienceUM1TR004403 · NCATS · UNIVERSITY OF IOWA · PI Marlan R Hansen, Patricia Winokur · 2023 to 2026
$16.1M
Foundation for the National Institutes of Health UM1TR004403NCATS NIH HHS UM1 TR004403U.S. Department of Defense W81XWH-18-1- 0658
6 · The paper itself

Abstract

backgroundAnkle-foot orthoses (AFO) design, including geometry and material selection, is tailored to meet specific clinical objectives. Understanding AFO mechanical behavior may provide insight into the effect of design considerations on the functional benefits to AFO users. Mechanical characteristics of AFOs are primarily assessed using strain gauges or computational modeling, both of which have limitations.

objectivesDetermine the test-retest reliability of weight-bearing carbon fiber dynamic AFO (CDO) surface strain measurements obtained using digital image correlation (DIC). STUDY

designProspective, randomized, cross-sectional reliability study.

methodsCDO displacement and surface strain were measured at three strut locations using DIC while 30 participants deflected the CDO into dorsiflexion at three time points. Test-retest reliability of strain measurements was assessed by intraclass correlation coefficient (ICC), minimum detectable change (MDC), and percentage MDC values.

resultsMinimum detectable change and ICC values were between 0.005%‒0.010% and 0.14‒0.76, respectively. Intraclass correlation coefficient were generally higher at more distal strut locations and larger ankle dorsiflexion angles, with a mean ICC across locations of 0.55. Proximal strain was 31%‒59% lower than strain in middle and distal regions, respectively. Lower absolute strain values in the proximal location resulted in higher average relative measurement error (12.2%) compared to the distal and middle locations (4.4% and 6.5%, respectively).

conclusionsThree-dimensional digital image correlation can provide reliable estimates of CDO surface strain, supporting its use for evaluating orthosis mechanical behavior. Better understanding of in vivo strain behavior across the CDO surface may assist with future device design and prescription to improve functional outcomes.

Indexed as

Carbon FiberFoot OrthosesAdultBiomechanical PhenomenaCross-Sectional StudiesEquipment DesignFemaleHumansMaleProspective StudiesReproducibility of ResultsStress, MechanicalWeight-BearingCarbon Fiberdigital image correlationpassive dynamic ankle foot orthosesreliabilitystrain analysis

Identifiers

PMID41084102
PMCPMC12758383

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.