Evidence map›Paper›PMID 41083367›Full record

ArticleNeurologia medico-chirurgica2025

Biomechanical Effects of Cage Position in Full-endoscopic Trans-Kambin's Triangle Lumbar Interbody Fusion: A Finite Element Analysis.

Masatoshi Morimoto, Sudharshan Tripathi, Niloufar Shekouhi, Vijay K Goel, Koichi Sairyo

Abstract read
In one paragraph

Article in Neurologia medico-chirurgica, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Masatoshi MorimotoDepartment of Orthopedic Surgery, Tokushima University Graduate School of Medicine.
Sudharshan TripathiDepartments of Bioengineering and Orthopaedics, Engineering Center for Orthopaedic Research Excellence, University of Toledo.
Niloufar ShekouhiDepartments of Bioengineering and Orthopaedics, Engineering Center for Orthopaedic Research Excellence, University of Toledo.
Vijay K GoelDepartments of Bioengineering and Orthopaedics, Engineering Center for Orthopaedic Research Excellence, University of Toledo.
Koichi SairyoDepartment of Orthopedic Surgery, Tokushima University Graduate School of Medicine.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Full-endoscopic trans-Kambin's triangle lumbar interbody fusion is considered a minimally invasive procedure. The cage position in Kambin's triangle lumbar interbody fusion differs from that in other types of lumbar interbody fusion; the cage is inserted via the foramen and placed diagonally to the endplate. Therefore, the ideal cage position remains uncertain. This study evaluated the biomechanical effects of different cage positions in Kambin's triangle lumbar interbody fusion at L4/5. An intact lumbar-to-femur finite element model was constructed. A diagonal line was first set with the foramen as the starting point, and this was used as the reference line [K(0°)] for the cage insertion angle. Five insertion angles were set: 10° and 20° anteriorly [K(10°) and K(20°)], 0° [K(0°)], and 10° and 20° posteriorly [K(-10°) and K(-20°)]. Range of motion and von Mises stress at the endplate were measured with the cage placed anteriorly, in the middle, and posteriorly for each angle (15 cage positions total). The mean range of motion at L4/5 was smallest for the middle cage position at K(0°) [K(0°)-Middle], followed by K(10°)-Middle. Endplate stress at L5 was 25.2 and 23.3 MPa for K(0°)-Middle and K(10°)-Middle, respectively (83.5 and 77.1% of the average for the 15 cage positions). Considering the range of motion and endplate stress, a central cage position [K(0°)-Middle and K(10°)-Middle] can effectively enhance stiffness at the fused segment, thereby contributing to stability. Moreover, reducing endplate stress at L5 may lower the risk of endplate collapse and cage subsidence. Therefore, it is desirable to place the cage in the center or slightly anterior to the center.

Indexed as

EndoscopyFinite Element AnalysisLumbar VertebraeSpinal FusionBiomechanical PhenomenaHumansRange of Motion, Articularbiomechanical studycage positionfinite element analysisfull endoscopetrans-Kambin's triangle lumbar interbody fusion

Identifiers

PMID41083367
PMCPMC12799340

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.