Evidence map›Paper›PMID 41082398›Full record

ArticleMagnetic resonance in medicine2026

Denoising Low-Power CEST Imaging Using a Deep Learning Approach With a Dual-Power Feature Preparation Strategy.

Yashwant Kurmi, Malvika Viswanathan, Leqi Yin, You Chen, Xiaoyu Jiang, Junzhong Xu, Zhongliang Zu

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yashwant KurmiVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA.ORCID https://orcid.org/0000-0003-4986-2106
Malvika ViswanathanVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA.ORCID https://orcid.org/0009-0001-9522-0780
Leqi YinVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA.
You ChenDepartment of Biomedical Informatics, Vanderbilt University Medical Center, Nashville, TN, USA.
Xiaoyu JiangVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA.ORCID https://orcid.org/0000-0002-0369-6301
Junzhong XuVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA.ORCID https://orcid.org/0000-0001-7895-4232
Zhongliang ZuVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA.ORCID https://orcid.org/0000-0001-7361-7480

Funding

Nuclear Overhauser enhancement (NOE) MR imaging of choline phospholipids and their metabolismR01EB029443 · NIBIB · VANDERBILT UNIVERSITY MEDICAL CENTER · PI ZU, ZHONGLIANG · 2021 to 2024
$1.5M
NIBIB NIH HHS R01 EB029443NIH HHS R01 EB029443
6 · The paper itself

Abstract

purposeLow-power (LP) chemical exchange saturation transfer (CEST) Z-spectra have significantly reduced confounding effects and enhanced peak resolvability, thereby improving the observation and quantification of various CEST effects. However, LP Z-spectra suffer greatly from reduced contrast-to-noise ratio (CNR). This study aims to develop a dual-power feature preparation for an autoencoder-based deep learning approach (DPDL), for denoising LP Z-spectra. This method leverages the high CNR of higher saturation power and the enhanced peak resolvability of low saturation power.

methodsThe DPDL model was trained on simulated CEST data, validated on both simulated and BSA phantoms, and then applied to measured data from rat brain and leg muscles at 4.7T. A Lorentzian difference (LD) analysis was used to quantify various CEST effects. Several evaluation metrics, including peak signal-to-noise ratio (PSNR), were used to assess the denoising performance. To demonstrate the advantage of the DPDL method, it was compared with the autoencoder-based method without feature preparation and various existing denoising methods that utilized a single LP Z-spectrum with two averages as input, thereby ensuring equivalent acquisition times.

resultsIn phantom experiments, the DPDL method demonstrated higher PSNR than existing denoising techniques, validating our approach. In animal experiments, the DPDL method showed improved image quality, outperforming existing denoising techniques. Additionally, several peaks from major tissue components in both brain and muscle were revealed on the LP Z-spectrum.

conclusionThe superior denoising performance using the DPDL for LP CEST imaging can enhance the isolation of various pools, thereby improving CEST applications, particularly at low fields.

Indexed as

Deep LearningImage Processing, Computer-AssistedMagnetic Resonance ImagingAlgorithmsAnimalsBrainComputer SimulationMuscle, SkeletalPhantoms, ImagingRatsRats, Sprague-DawleySignal-To-Noise Ratiochemical exchange saturation transfer (CEST)contrast‐to‐noise ratio (CNR)deep learning (DL)Lorentzian difference (LD) analysissignal‐to‐noise ratio (SNR)

Identifiers

PMID41082398
PMCPMC12746379

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.