Evidence map›Paper›PMID 41081847›Full record

ArticleEuropean spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society2026

First experience with a novel image guidance technology for posterior pedicle screw fixation: A cadaveric study on 2D/3D registration-based spine surgery.

Benno Bullert, Jula Gierse, Eric Mandelka, Holger Freischmidt, Kornelis Poelstra, Paul Alfred Gruetzner, Sven Yves Vetter

Abstract read
PubMed Publisher
In one paragraph

Article in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Benno BullertBG Klinik Ludwigshafen, Ludwigshafen, Germany.
Jula GierseBG Klinik Ludwigshafen, Ludwigshafen, Germany.
Eric MandelkaBG Klinik Ludwigshafen, Ludwigshafen, Germany.
Holger FreischmidtBG Klinik Ludwigshafen, Ludwigshafen, Germany.
Kornelis PoelstraThe Robotic Spine Institute, Las Vegas, United States.
Paul Alfred GruetznerBG Klinik Ludwigshafen, Ludwigshafen, Germany.
Sven Yves VetterBG Klinik Ludwigshafen, Ludwigshafen, Germany. sven.vetter@bgu-ludwigshafen.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeMinimally invasive pedicle screw insertion relies on imaging techniques due to limited anatomical visualization. A potential solution for intraoperative 3D guidance is using 2D/3D registration algorithms, which align intraoperative 2D X-rays with preoperatively acquired 3D datasets. This study aimed to evaluate the application of a novel 2D/3D image guidance software in posterior fixation with pedicle screws regarding accuracy, speed, and radiation exposure in a realistic clinical setting.

methodsFour human cadavers were instrumented with a total of 80 pedicle screws (from T8 to L5) by eight surgeons using 2D/3D image guidance. The surgeons, with varying levels of experience in spine surgery and navigation, utilized the software for the first time. Before the procedures, they underwent a structured one-hour training session. Accuracy, time parameters, and radiation exposure during pedicle screw insertion were assessed.

resultsAll K-wires were inserted correctly, demonstrating precise wire placement, regardless of the surgeons' experience. For pedicle screw placement, the 2D/3D image guidance achieved high accuracy of 95.0%, with no superior or inferior perforations. The mean time for each pedicle screw placement was 7.62 ± 2.83 min, with an average radiation exposure of 1.24 µSv per pedicle screw for the surgeon.

conclusionThe use of 2D/3D image guidance in this study demonstrated high precision in the placement of K-wires and pedicle screws. Consequently, 2D/3D image guidance presents a promising tool for both experienced and inexperienced users, facilitating precise 3D guidance of pedicle screws with a standard 2D C-arm.

Indexed as

Imaging, Three-DimensionalPedicle ScrewsSpinal FusionSurgery, Computer-AssistedCadaverFemaleHumansLumbar VertebraeComputer-AssistedFluoroscopyImage-GuidedIntraoperative imagingMinimally invasive surgical proceduresPedicle screwsSpinal fusion