ArticleQuantitative imaging in medicine and surgery2025
Impact of slab thickness in digital breast tomosynthesis on radiologists' diagnostic accuracy and interpretation time in women with breast cancer: a single-center retrospective study.
Article in Quantitative imaging in medicine and surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Controllable Cascade Aggregation Ion Programmed Nanomachines and Simple Isolation Enable Tumor-Derived Small Extracellular Vesicles Detection for Enhanced Breast Cancer Assessment.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Digital breast tomosynthesis (DBT) improves breast cancer detection compared to digital mammography but requires longer reading times. DBT slices are reconstructed and combined into thicker slabs. This study aimed to compare the diagnostic performance and interpretation time between a 6-mm thick slab and a 1-mm thin slice procedure in DBT, both using synthetic mammograms. Additionally, this study aimed to evaluate intra- and inter-observer agreement on image visibility. Methods: This retrospective study evaluated DBT performed on symptomatic women between September 2020 and June 2021. Two breast-certified radiologists independently interpreted DBT images from both procedures, with a 4-week washout period between interpretations. Of the 184 eligible women included, 97 had biopsy-proven malignancies, which consisted of 53 masses, 23 calcifications, 20 distortions, and 1 asymmetry. A Wilcoxon signed-rank test was used to compare reading times between each procedure. Sensitivity and specificity were evaluated using McNemar's test, while area under the receiver operating characteristic curve (AUC) was compared using the DeLong test. The non-inferiority of thick slab compared to thin slice of DBT was assessed using a one-sided confidence interval (CI). Observer agreement was measured using Cohen's kappa. Results: Sensitivity for the thick slab procedure of DBT was 91.8% (95% CI: 87.4-96.4%), while for thin slice procedure it was 95.9% (95% CI: 89.8-98.9%). The difference between two procedures was not statistically significant (P=0.39). Specificity for thick slab was 65.5% (95% CI: 58.6-75.4%), while for thin slice procedure it was 67.8% (95% CI: 56.9-77.4%). The difference between two procedures was not statistically significant (P=0.73). The AUC for thick slab was 0.79 (95% CI: 0.73-0.84), while for thin slice procedure it was 0.82 (95% CI: 0.77-0.87). No statistically significant difference between the two procedures was found (P=0.18). The mean interpretation time for thick slab was 11.2% (0.42 minutes) shorter compared to the thin slice procedure. The intra-rater agreement on image visibility between two procedures was 0.75 (95% CI: 0.65-0.81). Inter-rater agreement was 0.86 (95% CI: 0.84-0.87) for thick slab and 0.60 (95% CI: 0.59-0.61) for thin slice procedure. Conclusions: In this symptomatic patient cohort, the use of 6-mm thick slabs of DBT effectively reduced interpretation time without compromising diagnostic performance, demonstrating non-inferiority in sensitivity, specificity, and AUC for breast cancer detection compared to 1-mm slice standard DBT. Given the limited cohort size, further validation in a broader screening or asymptomatic population would be beneficial.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.