Evidence map›Paper›PMID 41081235›Full record

ArticleQuantitative imaging in medicine and surgery2025

Feasibility of finger-pulse triggering as a substitute for electrocardiogram triggering in cardiac magnetic resonance T1 mapping: a prospective comparative study.

Ziyi Pan, Zhaoxia Yang, Jinyang Wen, Lingping Ran, Xianghu Yan, Yi Luo, Lu Huang, Liming Xia, Dazhong Tang

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Ziyi Pan *Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Zhaoxia Yang *Department of Radiology, Xinqiao Hospital and The Second Affiliated Hospital, Army Medical University (Third Military Medical University), Chongqing, China.
Jinyang WenDepartment of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Lingping RanDepartment of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Xianghu YanDepartment of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Yi LuoDepartment of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Lu HuangDepartment of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Liming XiaDepartment of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Dazhong TangDepartment of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.ORCID https://orcid.org/0009-0001-0614-4238

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Electrocardiogram (ECG) triggering in cardiac magnetic resonance (MR) faces limitations with high-field systems (≥3.0T) due to magnetohydrodynamic (MHD) artifacts. This study aimed to evaluate the feasibility of using finger-pulse triggering for cardiac MR T1 mapping by comparing image quality and native T1 quantification with conventional ECG triggering. Methods: Patients who underwent cardiac MR examination between March and April 2024 were prospectively and consecutively enrolled in the study. All the patients underwent identical pre-contrast T1 mapping with both ECG- and pulse-triggering acquisitions using a modified Look-Locker inversion-recovery (MOLLI) 5(3)3 sequence, covering short-axis views at basal, mid, and apical slices of the left ventricle. Three radiologists independently evaluated image quality using the Likert scale (range, 1-5). Two radiologists manually delineated myocardial regions of interest (ROIs) on native T1 maps to quantify segmental native T1 values. Paired Results: A total of 15 participants were included in the study (mean age: 41±19 years; 60% male). ECG and finger-pulse triggering demonstrated equivalent diagnostic image quality (median scores: 4.0 Conclusions: Finger-pulse triggering demonstrates comparable accuracy and reliability to ECG triggering in cardiac MR T1 mapping, offering a viable clinical alternative for patients with ECG distortion or triggering failure.

Indexed as

Cardiac magnetic resonance (cardiac MR)electrocardiogram triggering (ECG triggering)magnetohydrodynamic effect (MHD effect)pulse triggeringT1 mapping

Identifiers

PMID41081235
PMCPMC12514587

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.