Evidence map›Paper›PMID 41081154›Full record

ArticleQuantitative imaging in medicine and surgery2025

Multiplexed sensitivity encoding diffusion-weighted imaging in the assessment of meningiomas: improving the image quality, grading accuracy, and proliferative activity evaluation.

Danjie Lin, Sihui Liu, Xiaodan Chen, Ye Li, Yichao Zhang, Yizhu Chen, Xiaofang Zhou, Hui Zheng, Lingmin Zheng, Peirong Jiang and 4 more

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Danjie Lin *Department of Radiology, Fujian Medical University Union Hospital, Fuzhou, China.
Sihui Liu *Department of Radiology, Fujian Medical University Union Hospital, Fuzhou, China.
Xiaodan Chen *Department of Radiology, Fujian Medical University Union Hospital, Fuzhou, China.
Ye LiDepartment of Radiology, Fujian Medical University Union Hospital, Fuzhou, China.
Yichao ZhangDepartment of Radiology, Fujian Medical University Union Hospital, Fuzhou, China.
Yizhu ChenDepartment of Radiology, Fujian Medical University Union Hospital, Fuzhou, China.
Xiaofang ZhouDepartment of Radiology, Fujian Medical University Union Hospital, Fuzhou, China.
Hui ZhengDepartment of Radiology, Fujian Medical University Union Hospital, Fuzhou, China.
Lingmin ZhengDepartment of Radiology, Fujian Medical University Union Hospital, Fuzhou, China.
Peirong JiangDepartment of Radiology, Fujian Medical University Union Hospital, Fuzhou, China.
Tianjin ZhongDepartment of Radiology, Fujian Medical University Union Hospital, Fuzhou, China.
Jialu ZhangGE Healthcare, Beijing, China.
Yunjing Xue *Department of Radiology, Fujian Medical University Union Hospital, Fuzhou, China.
Lin Lin *Department of Radiology, Fujian Medical University Union Hospital, Fuzhou, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Meningiomas often occur near the skull, where tumor imaging is prone to distortion and susceptibility artifacts, resulting in an unsatisfactory image quality of conventional single-shot echo-planar diffusion-weighted imaging (ssEPI-DWI). Our aim in this study was to evaluate the image quality of multiplexed sensitivity encoding diffusion-weighted imaging (MUSE-DWI) in meningiomas and the accuracy of the apparent diffusion coefficient (ADC) histogram parameters for tumor grading and proliferative activity evaluation based on MUSE-DWI and ssEPI-DWI. Methods: A total of 73 consecutive patients with pathologically confirmed meningiomas were included in this prospective study. Three neuroradiologists independently assessed the image quality using a 5-point Likert scale, whereas two other neuroradiologists quantitatively calculated the signal-to-noise ratio of lesion (SNR Results: Sharpness, distortion, artifact, lesion conspicuity, and overall image quality were significantly better in MUSE-DWI than those in ssEPI-DWI, with good agreement among the three raters (P<0.05; ICC: 0.83-0.90), whereas there was no significant difference in diagnostic confidence between the two DWI sequences (P>0.05; ICC: 0.80-0.82). The values of SNR Conclusions: Compared with ssEPI-DWI, MUSE-DWI improves the diffusion image quality of meningiomas, enhancing the accuracy of meningioma grading and proliferative activity evaluation.

Indexed as

diffusion-weighted imaging (DWI)imaging qualityMeningiomasmultiplexed sensitivity encoding (MUSE)tumor grading

Identifiers

PMID41081154
PMCPMC12514715

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.