ArticleACS omega2025
Quality-by-Design-Driven RP-HPLC Method Development and Validation for Impurity Analysis of Elexacaftor, a Cystic Fibrosis Drug, with LC-MS/MS-Based Degradant Identification.
Article in ACS omega, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The development and validation of an analytical technique based on RP-HPLC for the determination of impurities in Elexacaftor (ELX). Using a straightforward and stability-indicating HPLC technique, six known contaminants were precisely assessed with the right resolutions and peak forms. In a number of separation studies, the chromatographic separation was accomplished using an XBridge Shield RP 18, 150 mm × 4.6 mm, 3.5 μm column. The mobile phases consisted of methanol, acetonitrile, 2-propanol, and 10 mM potassium dihydrogen orthophosphate buffer used for the analysis. The gradient elution process took 90 min to complete, and the column temperature was 27 °C. Photodiode array optimization was accomplished at 220 nm with a 0.7 mL/min flow rate. The developed procedure was validated following ICH requirements and discovered to be robust, linear, accurate, specific, selective, and exact. The method range extended from LOQ to ∼0.45% for impurities and LOQ to ∼120% for the Elexacaftor drug substance. The method robustness was established by utilizing the DoEs in the part of the QbD concept. The method's stability was evaluated under diverse conditions including acid and base hydrolysis, oxidative and water hydrolysis, and thermal and photolytic degradation and was helpful for process development as well as quality checks in bulk drug manufacturing.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.