ArticleMagnetic resonance in medicine2026

High-resolution deuterium metabolic imaging of the human brain at 9.4 T using phase-cycled balanced SSFP spectral-spatial acquisitions.

Praveen Iyyappan Valsala, Rolf Pohmann, Rahel Heule, Georgiy A Solomakha, Nikolai I Avdievich, Jörn Engelmann, Laura Kuebler, André F Martins, Klaus Scheffler

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Praveen Iyyappan ValsalaHigh Field Magnetic Resonance, Max-Planck Institute for Biological Cybernetics, Tübingen, Germany.ORCID 0009-0009-9184-2206
Rolf PohmannHigh Field Magnetic Resonance, Max-Planck Institute for Biological Cybernetics, Tübingen, Germany.ORCID 0000-0002-6137-9590
Rahel HeuleHigh Field Magnetic Resonance, Max-Planck Institute for Biological Cybernetics, Tübingen, Germany.ORCID 0000-0002-4589-6483
Georgiy A SolomakhaHigh Field Magnetic Resonance, Max-Planck Institute for Biological Cybernetics, Tübingen, Germany.ORCID 0000-0002-3024-0545
Nikolai I AvdievichHigh Field Magnetic Resonance, Max-Planck Institute for Biological Cybernetics, Tübingen, Germany.ORCID 0000-0001-7608-0869
Jörn EngelmannHigh Field Magnetic Resonance, Max-Planck Institute for Biological Cybernetics, Tübingen, Germany.
Laura KueblerWerner Siemens Imaging Center, Department for Preclinical Imaging and Radiopharmacy, Eberhard Karls University Tübingen, Tübingen, Germany.
André F MartinsWerner Siemens Imaging Center, Department for Preclinical Imaging and Radiopharmacy, Eberhard Karls University Tübingen, Tübingen, Germany.ORCID 0000-0002-0171-0261
Klaus SchefflerHigh Field Magnetic Resonance, Max-Planck Institute for Biological Cybernetics, Tübingen, Germany.ORCID 0000-0001-6316-8773

Funding

Bundesministerium für Bildung und Forschung 01GQ1805BDKTK German Cancer ConsortiumEuropean Research Council 834940German Research Foundation SCHE658/S2Max-Planck-Gesellschaftthe Alexander von Humboldt Foundationthe Werner Siemens FoundationUniversity of Tuebingen, Germany
6 · The paper itself

Abstract

purposeThe aim was to improve the sensitivity and robustness against B

methodsWe investigated two variants of phase-cycled bSSFP acquisitions, namely uniformly weighted multi-echo and acquisition-weighted chemical shift imaging (CSI) to improve the SNR of DMI in the brain after oral [6,6'-

resultsHigh-resolution whole-brain dynamic DMI maps were obtained for all acquisitions. The CSI variant of phase-cycled bSSFP achieved an average SNR increase of 16% and 25% for glucose and glutamate + glutamine (Glx), respectively, compared to the SNR-optimized vendor's standard CSI. Phase-cycling improved the bSSFP metabolite estimation and provided additional spectral encoding at the cost of a 10% to 20% SNR loss. Compared to the CSI variant of bSSFP acquisition, the multi-echo variant exhibited up to 35% lower SNR performance because of uniform k-space weighting and less efficient readout. However, it achieved higher resolutions than acquisition-weighted CSI protocols and showed several qualitative improvements.

conclusionWe demonstrated the feasibility of using two phase-cycled bSSFP acquisitions for off-resonance insensitive high-resolution [6,6'-

Indexed as

BrainDeuteriumImage Processing, Computer-AssistedMagnetic Resonance ImagingAdultAlgorithmsFemaleGlucoseHumansMaleSignal-To-Noise RatioDeuteriumGlucosebSSFPdeuterium metabolic imagingIDEALSNRultra‐high‐field

Identifiers

PMID41078150
PMCPMC12746357

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.