Evidence map›Paper›PMID 41077931›Full record

ArticleUltrasonography (Seoul, Korea)2025

Comparison between vibration-controlled transient elastography and point shear wave elastography for assessment of hepatic fibrosis based on magnetic resonance elastography.

Tatsuya Gotoh, Takashi Kumada, Sadanobu Ogawa, Fumihiko Niwa, Hidenori Toyoda, Tomoyuki Akita, Junko Tanaka, Masahito Shimizu

Abstract read
In one paragraph

Article in Ultrasonography (Seoul, Korea), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Tatsuya GotohDepartment of Imaging Diagnosis, Ogaki Municipal Hospital, Ogaki, Japan.
Takashi KumadaGifu Kyoritsu University, Ogaki, Japan.
Sadanobu OgawaDepartment of Imaging Diagnosis, Ogaki Municipal Hospital, Ogaki, Japan.
Fumihiko NiwaDepartment of Imaging Diagnosis, Ogaki Municipal Hospital, Ogaki, Japan.
Hidenori ToyodaDepartment of Gastroenterology and Hepatology, Ogaki Municipal Hospital, Ogaki, Japan.
Tomoyuki AkitaDepartment of Epidemiology, Infectious Disease Control, and Prevention, Hiroshima University Institute of Biomedical and Health Sciences, Hiroshima, Japan.
Junko TanakaDepartment of Epidemiology, Infectious Disease Control, and Prevention, Hiroshima University Institute of Biomedical and Health Sciences, Hiroshima, Japan.
Masahito ShimizuDepartment of Gastroenterology/Internal Medicine, Graduate School of Medicine, Gifu University, Gifu, Japan.

Funding

FUJIFILM Medical Service Solution Co., Ltd.
6 · The paper itself

Abstract

purposeThis study prospectively compared the diagnostic accuracy of vibration-controlled transient elastography (VCTE) and point shear wave elastography (pSWE) in the assessment of liver fibrosis, versus a reference standard of magnetic resonance elastography (MRE).

methodsThis study prospectively enrolled patients with chronic liver disease, who underwent pSWE, VCTE, and MRE. Fibrosis was staged based on liver stiffness (LS) values measured using MRE: F0 (<2.61 kPa), F1 (≥2.61 to <2.97 kPa), F2 (≥2.97 to <3.62 kPa), F3 (≥3.62 to <4.69 kPa), and F4 (≥4.69 kPa). Each modality was performed independently, and the results were blinded to minimize bias. Diagnostic performance was assessed using the Pearson correlation coefficient (CC), Lin concordance correlation coefficient (CCC), area under the receiver operating characteristic curve (AUROC), Obuchowski index, integrated discrimination improvement (IDI), and net reclassification improvement (NRI).

resultsIn total, 251 patients (median age, 64 years; 97 women) were evaluated. Both pSWE (CC, 0.838; CCC, 0.825) and VCTE (CC, 0.803; CCC, 0.784) demonstrated strong correlations with MRE, with no statistically significant differences. AUROC values for diagnosing fibrosis stage were comparable between pSWE and VCTE. Based on the Obuchowski index, pSWE provided closer agreement with MRE in detecting ≥F1, ≥F2, and ≥F4. Analyses of IDI and NRI also displayed significantly better agreement between pSWE and MRE in detecting ≥F1, ≥F2, and ≥F4 (NRI: P<0.001; IDI: F1 and F2, P<0.001; F4, P=0.002).

conclusionpSWE demonstrated closer alignment than VCTE with LS values measured by MRE, suggesting the potential of pSWE for noninvasively assessing liver fibrosis.

Indexed as

Elasticity imaging techniquesLiver cirrhosisMagnetic resonance imagingROC curveUltrasonography

Identifiers

PMID41077931
PMCPMC12645073

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.