A low-cost, easy-to-implement optical add-on to convert a retinal OCT into a ultra-high-resolution corneal OCT.

Fritz Stange, Sebastian Bohn, Alois Gottschlich, Tobias Korn, Oliver Stachs, Karsten Sperlich

Abstract read
In one paragraph

Article in Zeitschrift fur medizinische Physik, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Fritz StangeDepartment of Ophthalmology, Rostock University Medical Center, 18057 Rostock, Germany; Institute of Physics, University of Rostock 18059 Rostock, Germany.
Sebastian BohnDepartment of Ophthalmology, Rostock University Medical Center, 18057 Rostock, Germany; Department Life, Light & Matter, University of Rostock 18059 Rostock, Germany.
Alois GottschlichDepartment of Ophthalmology, Rostock University Medical Center, 18057 Rostock, Germany.
Tobias KornInstitute of Physics, University of Rostock 18059 Rostock, Germany; Department Life, Light & Matter, University of Rostock 18059 Rostock, Germany.
Oliver StachsDepartment of Ophthalmology, Rostock University Medical Center, 18057 Rostock, Germany; Department Life, Light & Matter, University of Rostock 18059 Rostock, Germany.
Karsten SperlichDepartment of Ophthalmology, Rostock University Medical Center, 18057 Rostock, Germany; Department Life, Light & Matter, University of Rostock 18059 Rostock, Germany. Electronic address: karsten.sperlich@uni-rostock.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeCommercial anterior segment optical coherence tomography (OCT) systems typically offer sufficient axial resolution to distinguish corneal layers. However, their lateral resolution (∼15-20 µm) is limited, restricting the visualization of fine microstructural features, relevant for noninvasive diagnosis of corneal pathologies. We present a low-cost, easy-to-implement optical add-on that substantially improves the lateral resolution of a standard retinal OCT system, enabling high-fidelity corneal imaging.

methodsCustom-designed optical modules were developed for the standard objective lens of an investigational retinal OCT device. The system design, incorporating a single achromatic lens, was optimized through optical simulations to achieve a higher numerical aperture and reduced focal length. The lateral resolution was evaluated both theoretically, via point spread function, and experimentally using a 1951 United States Air Force (USAF) resolution target. A compact prototype, presented here, was tested on a commercial SPECTRALIS OCT2, compared with the commercial Anterior Segment Module (both Heidelberg Engineering GmbH, Heidelberg, Germany), and tested in vivo on two human subjects, including one with suspected epithelial basement membrane dystrophy (EBMD).

resultsThe prototype achieved a lateral resolution of 3.1µm in the experiment, closely matching the results of the optical simulation. This resolution is markedly better than the 15.6µm achieved with the commercial corneal OCT, albeit at a cost of a reduced field of view (2.62mm vs. 8.29mm). In vivo imaging confirmed enhanced visualization of epithelial microstructures in both healthy and pathological corneas, despite a reduced depth of focus resulting from the higher numerical aperture.

conclusionThe proposed add-on enabled ultra-high-resolution corneal imaging on a standard SPECTRALIS OCT2 platform without the need for major hardware modifications, such as an increased reference arm or dispersion compensation. This low-cost, easy-to-implement approach offers diagnostic value for early detection and longitudinal monitoring of subtle corneal irregularities, particularly in conditions such as EBMD, where a high lateral resolution is critical for clinical decision-making.

Indexed as

CorneaRetinaTomography, Optical CoherenceEquipment DesignHumansReproducibility of Resultsanterior segmentCorneaEBMDhigh-resolutionOCT

Identifiers

PMID41076352
PMCPMC13316523

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.