Evidence map›Paper›PMID 41073813›Full record

ArticleSurgical endoscopy2026

Do segmentation metrics reflect clinical reality? A surgeon-centered evaluation in robot-assisted minimally invasive esophagectomy.

Ronald de Jong, Yiping Li, Romy van Jaarsveld, Gino Kuiper, Richard van Hillegersberg, Jelle Ruurda, Josien Pluim, Marcel Breeuwer, Yasmina Al Khalil

Abstract read
In one paragraph

Article in Surgical endoscopy, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Ronald de JongDepartment of Biomedical Engineering, Eindhoven University of Technology, Groene Loper 3, 5612 AE, Eindhoven, The Netherlands. r.l.p.d.d.jong@tue.nl.ORCID 0009-0005-7806-4340
Yiping LiDepartment of Biomedical Engineering, Eindhoven University of Technology, Groene Loper 3, 5612 AE, Eindhoven, The Netherlands.
Romy van JaarsveldDepartment of Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands.
Gino KuiperDepartment of Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands.
Richard van HillegersbergDepartment of Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands.
Jelle RuurdaDepartment of Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands.
Josien PluimDepartment of Biomedical Engineering, Eindhoven University of Technology, Groene Loper 3, 5612 AE, Eindhoven, The Netherlands.
Marcel BreeuwerDepartment of Biomedical Engineering, Eindhoven University of Technology, Groene Loper 3, 5612 AE, Eindhoven, The Netherlands.
Yasmina Al KhalilDepartment of Biomedical Engineering, Eindhoven University of Technology, Groene Loper 3, 5612 AE, Eindhoven, The Netherlands.

Funding

Hanarth Fonds 2022-13Nederlandse Organisatie voor Wetenschappelijk Onderzoek KICH1.ST03.21.019Nederlandse Organisatie voor Wetenschappelijk Onderzoek OCENW.M.21.377
6 · The paper itself

Abstract

backgroundDeep learning-based anatomy segmentation holds promise for improving real-time guidance in complex surgeries such as robot-assisted minimally invasive esophagectomy (RAMIE). However, the clinical relevance of commonly used metrics for evaluating segmentation quality remains unclear, as previous assessments have lacked direct input from surgeons. This study aims to assess how well quantitative segmentation metrics reflect surgeons' assessments of anatomical overlay accuracy and clinical usefulness during RAMIE.

methodsWe conducted a survey involving 26 upper gastrointestinal surgeons, including both trainee and attending surgeons, who assessed video clips of RAMIE procedures featuring deep learning-generated anatomical overlays. We correlated the surgeons' qualitative evaluations of annotation accuracy and clinical usefulness with a comprehensive set of quantitative metrics, including overlap, distance, temporal, and error-specific measures. The analysis encompassed over 8000 manually annotated frames from 12 video clips, with overlays generated by two state-of-the-art deep learning models.

resultsOverlap and temporal consistency metrics show the strongest correlation with surgeon assessments. Distance-based and error-specific metrics correlate moderately. Novices show weaker correlations and tend to rate overlays more leniently. Qualitative feedback reveals issues like hallucinations and instability, often missed by current metrics.

conclusionStandard quantitative metrics partially reflect surgeon perceptions but should be complemented by surgeon-informed evaluations and task-specific metrics to better capture clinically relevant errors. Aligning metric design with surgical expertise is essential for the safe and effective integration of AI-guided anatomical segmentation in the operating room.

Indexed as

Clinical CompetenceDeep LearningEsophagectomyRobotic Surgical ProceduresSurgeonsHumansMaleMinimally Invasive Surgical ProceduresAnatomy recognitionDeep learningEvaluation metricsRobot-assisted surgerySemantic segmentationSurvey

Identifiers

PMID41073813
PMCPMC12823753

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.