Evidence map›Paper›PMID 41070749›Full record

ArticleLab on a chip2025

On-chip particle levitation and micromanipulation using bulk acoustic waves.

Emilie Vuille-Dit-Bille, Marc-Alexandre Dubois, Junsun Hwang, Dara Bayat, Thomas Overstolz, Amit Dolev, Sarah Heub, Gilles Weder, Michel Despont, Mahmut Selman Sakar

Abstract read
In one paragraph

Article in Lab on a chip, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Emilie Vuille-Dit-BilleCSEM SA, Neuchâtel, Switzerland. thomas.overstolz@csem.ch.ORCID http://orcid.org/0000-0002-5700-2862
Marc-Alexandre DuboisCSEM SA, Neuchâtel, Switzerland. thomas.overstolz@csem.ch.
Junsun HwangInstitute of Mechanical Engineering, EPFL, Lausanne, Switzerland. selman.sakar@epfl.ch.ORCID http://orcid.org/0000-0002-6524-8379
Dara BayatCSEM SA, Neuchâtel, Switzerland. thomas.overstolz@csem.ch.
Thomas OverstolzCSEM SA, Neuchâtel, Switzerland. thomas.overstolz@csem.ch.
Amit DolevInstitute of Mechanical Engineering, EPFL, Lausanne, Switzerland. selman.sakar@epfl.ch.
Sarah HeubCSEM SA, Neuchâtel, Switzerland. thomas.overstolz@csem.ch.ORCID http://orcid.org/0000-0003-2016-9543
Gilles WederCSEM SA, Neuchâtel, Switzerland. thomas.overstolz@csem.ch.ORCID http://orcid.org/0000-0002-0321-8756
Michel DespontCSEM SA, Neuchâtel, Switzerland. thomas.overstolz@csem.ch.
Mahmut Selman SakarInstitute of Mechanical Engineering, EPFL, Lausanne, Switzerland. selman.sakar@epfl.ch.ORCID http://orcid.org/0000-0002-7226-3382

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Acoustofluidic technologies enable precise manipulation of microscale objects using travelling and standing sound waves in physiological fluids, offering exciting capabilities for biomedical and chemical applications. In particular, surface acoustic wave-based devices have shown great promise for on-chip micromanipulation, but their planar transducer configuration limits the usable workspace near the microchannel surface. Here, we present a novel acoustofluidic platform based on a digitally addressable array of piezoelectric micromachined ultrasound transducers (PMUTs) that generate bulk acoustic waves and acoustic traps within three-dimensional (3D) fluidic chambers. Through a combination of finite element modelling and experimental measurements, we quantify the acoustic field distribution and study acoustic trap formation dynamics. We demonstrate deterministic 3D levitation of particles in water at rest and under continuous flow by generating standing acoustic waves across the height of the chamber. Our results show that 30 μm polystyrene particles can be levitated to a pressure node generated 640 μm above the surface with less than 6% positional error. The system applies in-plane acoustic radiation forces as high as 90 pN to keep the particles in the trap under flow rates up to 40 μL min

Identifiers

PMID41070749
PMCPMC12512227

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.