The Effect of Implant Size on Fretting Currents of Acetabular Cup-Liner Tapers During in Vitro Cyclic Loading.
Article in Journal of orthopaedic research : official publication of the Orthopaedic Research Society, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
As dual mobility hips become more popular, there is a clinical need to investigate design features that will impact tribocorrosion of these devices. While previous studies have investigated both corrosion and wear damage, the effect of device size on fretting corrosion response has yet to be evaluated. In this study, we compare two implants of the same design (EMPHASYS Hip Solution) but with different-sized acetabular cups (66 mm vs 44 mm) representing the range of sizes typically used. We hypothesized that the smaller implant would perform better due to the smaller taper engagement area and the smaller moments imparted during normal activities. Each device underwent a physiologically representative intermittent cyclic load between 400 N and 4000 N in 50,000 cycle increments with pauses in between, up to a total of 3,000,000 cycles and 110 h at 9 Hz in phosphate-buffered saline (PBS). Under potentiostatic control (-50 mV vs Ag/AgCl), fretting corrosion currents were generated and monitored with intermittent measurement of baseline currents. Post-testing, solution ion levels were measured using inductively coupled mass spectrometry (ICP-MS). Results showed there was no difference between devices when comparing average current, average cumulative charge, average decay constant (s-), total volume lost and solution ion levels. We report a total volume loss of 0.0028 ± 0.0015 mm