Evidence map›Paper›PMID 41070087›Full record

ArticleFrontiers in cardiovascular medicine2025

Transthoracic echocardiography-guided subaortic ventricular septal defect closure in infants: a case report.

Radityo Prakoso, Rina Ariani, Yovi Kurniawati, Brian Mendel, Oktavia Lilyasari

Abstract readCase Reports
In one paragraph

Article in Frontiers in cardiovascular medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Radityo PrakosoDivision of Pediatric Cardiology and Congenital Heart Disease, Department of Cardiology and Vascular Medicine, National Cardiovascular Centre of Harapan Kita, Universitas Indonesia, Jakarta, Indonesia.
Rina ArianiDivision of Non-invasive Diagnostic and Cardiovascular Imaging, Department of Cardiology and Vascular Medicine, National Cardiovascular Centre of Harapan Kita, Universitas Indonesia, Jakarta, Indonesia.
Yovi KurniawatiDivision of Pediatric Cardiology and Congenital Heart Disease, Department of Cardiology and Vascular Medicine, National Cardiovascular Centre of Harapan Kita, Universitas Indonesia, Jakarta, Indonesia.
Brian MendelDepartment of Cardiology and Vascular Medicine, National Cardiovascular Centre of Harapan Kita, Universitas Indonesia, Jakarta, Indonesia.
Oktavia LilyasariDivision of Pediatric Cardiology and Congenital Heart Disease, Department of Cardiology and Vascular Medicine, National Cardiovascular Centre of Harapan Kita, Universitas Indonesia, Jakarta, Indonesia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Subaortic VSD, while similar to perimembranous defects, pose a higher risk for aortic valve insufficiency and AV block. This case aims to assess the safety and efficacy of percutaneous subaortic VSD closure in infants under 10 kg using transthoracic echocardiography-only guidance. Case presentation: A one-year-old infant, 8.9 kg, was scheduled for subaortic VSD closure due to concerns of failure to thrive. Percutaneous closure was performed using a retrograde transarterial approach with a 7/5 mm Konar-MF VSD Occluder (Lifetech) under TTE guidance. Apical 5-chamber view showed smallest VSD diameter 3.8 mm. 3.5/5F Guiding JR catheter with soft hydrophilic wire were then maneuvered to descending aorta in subxiphoid 12 o'clock view, suprasternal short axis view and positioned just above the aortic valve. Catheter was then entered to the LV shown by parasternal long axis view. 3.5/5F Guiding JR catheter was then crossed the subaortic VSD in parasternal short axis view. The Konar-MF VSD Occluder (Lifetech) No. 7/5 mm was deployed assisted by apical 5-chamber view. Device detachment was then evaluated in parasternal short axis view showing no residual shunt. At six-month follow-up, the device was well seated, and the symptoms subsided. Conclusions: Our case underscores that zero-fluoroscopy TTE-only percutaneous subaortic VSD closure is feasible in selected patients under 10 kg with no major complications.

Indexed as

case reportsmall body weightsubaortic VSDTTEzero-fluoroscopy

Identifiers

PMID41070087
PMCPMC12504355

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.