Evidence map›Paper›PMID 41068538›Full record

ArticlePediatric cardiology2026

Early Outcomes of Self-expanding VenusP-valve Implantation in Dysfunctional Right Ventricular Outflow Tracts in Pediatric Patients: A Single-Center Evolving Experience.

Sebastian Góreczny, Maksym Lazu, Marc Gewillig, Mariusz Stańczyk, Andrzej Rudziński, Reinhardt Becht, Phouc Duong, Michał Wyrobek, Shakeel Qureshi

Abstract read
In one paragraph

Article in Pediatric cardiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Sebastian GórecznyDepartment of Paediatric Cardiology, University Children's Hospital, Jagiellonian University Medical College, Krakow, Poland. sebastian.goreczny@uj.edu.pl.
Maksym LazuDepartment of Paediatric Cardiology, University Children's Hospital, Jagiellonian University Medical College, Krakow, Poland.
Marc GewilligDepartment Pediatric Cardiology, University Hospitals Leuven, Louvain, Belgium.
Mariusz StańczykDepartment of Paediatric Cardiology, University Children's Hospital, Jagiellonian University Medical College, Krakow, Poland.
Andrzej RudzińskiDepartment of Paediatric Cardiology, University Children's Hospital, Jagiellonian University Medical College, Krakow, Poland.
Reinhardt BechtVenus Medtech Europe, Amsterdam, The Netherlands.
Phouc DuongDepartment of Cardiology and Cardiovascular Surgery, Alder Hey Children's Hospital, Liverpool, UK.
Michał WyrobekDepartment of Radiology, University Children's Hospital, Jagiellonian University Medical College, Krakow, Poland.
Shakeel QureshiDepartment of Pediatric and Adult Congenital Heart Disease, Evelina London Children's Hospital, Guy's and St. Thomas' NHS Foundation Trust, London, UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Recent introduction into clinical practice of large self-expanding valves addressees the issue of dilated dysfunctional right ventricular outflow tracts (RVOTs). The purpose of this study was to determine the safety and short-term efficacy of the VenusP-valve (Venus MedTech) implantation in the pulmonary position in the pediatric group of patients with emphasis on the evolving qualification criteria and implantation techniques. Over a 14-month period, 15 patients < 18 years-old with severe pulmonary regurgitation underwent successful PPVI with the self-expanding VenusP-valve. All types of RVOT anatomies were represented in the study group. Desired valve position during the first attempt was achieved in 13 patients (87%). When compared between the first and second half of the study period, there was a significant difference toward less oversizing: 3.3 ± 1.4 mm versus 1.8 ± 0.7 mm, p = 0.039. On final angiography, trivial pulmonary regurgitation was present in 9 patients (60%). In the remaining 6 patients (40%), the valve was competent. Adverse events were limited to two patients (13.3%) with transient rhythm disturbances without any clinical sequelae. During a median follow-up of 11.5 months (range 7.9-21 months), all the valves remained normally functioning with no need for reinterventions and no episodes of infective endocarditis. The VenusP-valve implantation was safely and effectively performed in pediatric patients with all types of large dysfunctional RVOTs. With modified techniques of implantation, limited femoral vein access or stented pulmonary artery branches, the valves can be successfully implanted.

Indexed as

Heart Valve ProsthesisHeart Valve Prosthesis ImplantationPulmonary ValvePulmonary Valve InsufficiencyVentricular Outflow Obstruction, RightAdolescentCardiac CatheterizationChildChild, PreschoolFemaleFollow-Up StudiesHumansInfantMaleProsthesis DesignRetrospective StudiesPrecautious pulmonary valve implantationPulmonary regurgitationTranscatheter pulmonary valve implantation

Identifiers

PMID41068538
PMCPMC13498636

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.