Evidence map›Paper›PMID 41068282›Full record

ArticleScientific reports2025

Finite element analysis of implant selection and screw positioning in proximal femoral basicervical fractures.

Tianhao Yang, Faez Noraddin, Baozhe Liu, Zegen Zhang, Hai-Lun Gu

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Tianhao YangDepartment of Traumatic Orthopedics, Shengjing Hospital, China Medical University, Shenyang, Liaoning Province, China.ORCID http://orcid.org/0009-0007-3762-6831
Faez NoraddinOrthopedics Department, Typical Police Hospital, Sana'a City, Yemen.ORCID http://orcid.org/0009-0005-1640-8160
Baozhe LiuDepartment of Traumatic Orthopedics, Shengjing Hospital, China Medical University, Shenyang, Liaoning Province, China.ORCID http://orcid.org/0000-0002-4937-8851
Zegen ZhangDepartment of Traumatic Orthopedics, Shengjing Hospital, China Medical University, Shenyang, Liaoning Province, China.ORCID http://orcid.org/0009-0007-8322-4454
Hai-Lun GuDepartment of Traumatic Orthopedics, Shengjing Hospital, China Medical University, Shenyang, Liaoning Province, China. guhailun_@163.com.ORCID http://orcid.org/0000-0001-5697-9818

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To determine the optimal implant for proximal femoral basicervical fractures by comparing the biomechanical properties of the Dynamic Hip Screw (DHS), Proximal Femoral Nail Anti-Rotation (PFNA), and InterTAN using finite element analysis (FEA). Five fixation configurations were simulated: DHS (central screw AP view), PFNA with central helical blade (PFNA-C), PFNA with inferior helical blade (PFNA-I), InterTAN with central hip screw (InterTAN-C), and InterTAN with inferior hip screw (InterTAN-I). Following construction and validation of an intact femur model, three progressively unstable basicervical fracture patterns (simple, intertrochanteric defect, lateral wall defect) were created and incorporated with the implants. FEA simulated a 700 N load (70 kg patient single-leg stance). Displacement and implant stress distribution were analyzed. Primary comparisons assessed DHS, PFNA-C, and InterTAN-C performance; secondary comparisons evaluated screw position (C vs. I) in cephalomedullary nails (CMN). For simple fractures, DHS, PFNA, and InterTAN exhibited minimal differences in displacement and implant stress. In intertrochanteric and lateral wall defect fractures, significant differences emerged. Displacement was significantly greater with DHS, followed by PFNA, then InterTAN (minimal PFNA-InterTAN difference). Maximum stress was highest with InterTAN, higher with PFNA than DHS, but remained below medical titanium fatigue limits. The inferior screw position demonstrated biomechanical advantages over the central position in CMNs. DHS, PFNA, and InterTAN are suitable for simple basicervical fractures. For fractures with intertrochanteric or lateral wall defects, CMNs (PFNA, InterTAN) provide superior stability over DHS, with InterTAN offering marginally better stability than PFNA. The inferior hip screw position is biomechanically preferable in CMNs.

Indexed as

Bone ScrewsFemoral FracturesFinite Element AnalysisFracture Fixation, InternalBiomechanical PhenomenaBone NailsFemurHip FracturesHumansStress, MechanicalBiomechanicsDynamic hip screwFinite element analysisInterTANPFNAProximal femoral basicervical fractures

Identifiers

PMID41068282
PMCPMC12511412

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.