Evidence map›Paper›PMID 41068157›Full record

ArticleScientific reports2025

Configuration and reduced-order modeling of a flow system based on experimental data.

Faisal Saleem, Alicja Wiora, Józef Wiora

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Faisal SaleemDepartment of Measurements and Control Systems, Silesian University of Technology, Gliwice, 44-100, Poland. faisal.saleem@polsl.pl.
Alicja WioraDepartment of Measurements and Control Systems, Silesian University of Technology, Gliwice, 44-100, Poland.
Józef WioraDepartment of Measurements and Control Systems, Silesian University of Technology, Gliwice, 44-100, Poland.

Funding

Silesian University of Technology 02/050/BK-25/0047
6 · The paper itself

Abstract

Regulated flow systems exhibit a variable dynamic behavior when subjected to distinct inputs. The significant non-linear behavior of the system at low inputs and the difference in the output pattern for the increase and decrease in flow pose challenges in modeling. One way is to identify separate sets of parameters for each input-output data set and develop distinct models. However, this approach is computationally expensive when designing a single controller covering the whole input range. To overcome the said limitation, we used a Principal Component Analysis (PCA) based estimation technique. The developed Linear Parameter Varying (LPV) dynamic model describes real measurement values of a laboratory flow system. The data treatment consists of (1) an automated input-output data acquisition, (2) [Formula: see text]-order model estimation from measured data, (3) the reduction of the dynamic parameters using PCA, and (4) the development of a reduced LPV model for the entire input range. The LPV model presents its output response comparable to the experimentally taken flow rates. The proposed modeling technique can help design a single controller sufficient to achieve the desired output applicable in the whole measuring range. The effectiveness of our approach suggests its use for synthesizing an LPV controller for flow systems.

Indexed as

Automated measurement methodLinear parameters varyingModel identificationModel-order reductionPrincipal component analysis

Identifiers

PMID41068157
PMCPMC12511434

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.