Evidence map›Paper›PMID 41066017›Full record

ArticlePhysical and engineering sciences in medicine2026

Artificial intelligence-based method for renal function automatic assessment of each kidney using plain computed tomography (CT) scans.

Rongchang Guo, Wei Xia, Feng Xu, Yaotian Qian, Qiuyue Han, Daoying Geng, Xin Gao, Yiwei Wang

Abstract read
PubMed Publisher
In one paragraph

Article in Physical and engineering sciences in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Rongchang Guo *Department of Urology, Shanghai Ninth People's Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, 200011, China.
Wei Xia *Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China.
Feng Xu *Department of Nuclear Medicine, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China.
Yaotian QianSuzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, Jiangsu, China.
Qiuyue HanDepartment of Radiology, Huashan Hospital, Fudan University, Shanghai, 200040, China.
Daoying GengDepartment of Radiology, Huashan Hospital, Fudan University, Shanghai, 200040, China. gengdaoying@huashan.org.cn.
Xin GaoSuzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, Jiangsu, China. gaox@sibet.ac.cn.
Yiwei WangDepartment of Urology, Shanghai Ninth People's Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, 200011, China. wang.yiwei@sjtu.edu.cn.ORCID http://orcid.org/0009-0004-6922-8991

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Separate renal function assessment is important in clinical decision making. The single-photon emission computed tomography is commonly used for the assessment although radioactive, tedious and of high cost. This study aimed to automatically assess the separate renal function using plain CT images and artificial intelligence methods, including deep learning-based automatic segmentation and radiomics modeling. We performed a retrospective study on 281 patients with nephrarctia or hydronephrosis from two centers (Training set: 159 patients from Center I; Test set: 122 patients from Center II). The renal parenchyma and hydronephrosis regions in plain CT images were automatically segmented using deep learning-based U-Net transformers (UNETR). Radiomic features were extracted from the two regions and used to build radiomic signature using the ElasticNet, then further combined with clinical characteristics using multivariable logistic regression to obtain an integrated model. The automatic segmentation was evaluated using the dice similarity coefficient (DSC). The mean DSC of automatic kidney segmentation based on UNETR was 0.894 and 0.881 in the training and test sets. The average time of automatic and manual segmentation was 3.4 s/case and 1477.9 s/case. The AUC of radiomic signature was 0.778 in the training set and 0.801 in the test set. The AUC of the integrated model was 0.792 and 0.825 in the training and test sets. It is feasible to assess the renal function of each kidney separately using plain CT and AI methods. Our method can minimize the radiation risk, improve the diagnostic efficiency and reduce the costs.

Indexed as

Artificial IntelligenceKidneyKidney Function TestsTomography, X-Ray ComputedAdultAgedAutomationFemaleHumansImage Processing, Computer-AssistedMaleMiddle AgedRetrospective StudiesArtificial intelligenceAutomatic segmentationNon-invasive imagingRenal function assessment

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.